Related Experiment Video
Updated: Apr 6, 2026

Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
Compound identification in gas chromatography/mass spectrometry-based metabolomics by blind source separation
Xavier Domingo-Almenara1, Alexandre Perera2, Noelia Ramírez1
1Metabolomics Platform - IISPV, Department of Electrical and Automation Engineering (DEEEA), Universitat Rovira i Virgili, Tarragona, Catalonia, Spain; CIBERDEM, Biomedical Research Networking Center in Diabetes and Associated Metabolic Disorders, Madrid, Spain.
Abstract:
Metabolomics GC-MS samples involve high complexity data that must be effectively resolved to produce chemically meaningful results. Multivariate curve resolution-alternating least squares (MCR-ALS) is the most frequently reported technique for that purpose. More recently, independent component analysis (ICA) has been reported as an alternative to MCR. Those algorithms attempt to infer a model describing the observed data and, therefore, the least squares regression used in MCR assumes that the data is a linear combination of that model. However, due to the high complexity of real data, the construction of a model to describe optimally the observed data is a critical step and these algorithms should prevent the influence from outlier data. This study proves independent component regression (ICR) as an alternative for GC-MS compound identification. Both ICR and MCR though require least squares regression to correctly resolve the mixtures. In this paper, a novel orthogonal signal deconvolution (OSD) approach is introduced, which uses principal component analysis to determine the compound spectra. The study includes a compound identification comparison between the results by ICA-OSD, MCR-OSD, ICR and MCR-ALS using pure standards and human serum samples. Results shows that ICR may be used as an alternative to multivariate curve methods, as ICR efficiency is comparable to MCR-ALS. Also, the study demonstrates that the proposed OSD approach achieves greater spectral resolution accuracy than the traditional least squares approach when compounds elute under undue interference of biological matrices.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
High-Resolution Mass Spectrometry (HRMS)

