Background:
Unattended home-based polysomnography (H-PSG) is a reliable tool for the diagnosis of obstructive sleep apnoea (OSA). The quality of the recording can be influenced by several factors including the set-up location - at home versus in the sleep laboratory. Previous studies have suggested that the failure rate is higher when H-PSG is fitted in hospital. The aim of this study was to determine the influence of hook-up location on H-PSG recording quality. Feasibility and repeatability of H-PSG were also assessed.
Methods:
Consecutive patients suspected of OSA were selected. Each patient underwent two H-PSGs within two weeks, one fitted at home and one fitted in the sleep laboratory. The order of H-PSG was randomly assigned.
Results:
Among the 102 included patients, 95 completed the study. Ninety-three per cent of the 190 H-PSGs were satisfactory. The failure rate of H-PSG was similar for both the home set-up and the sleep laboratory set-up (p = 0.33). Seventy-nine per cent of patients opted to be fitted at home. OSA was diagnosed in 59%. The apnoea-hypopnoea index was similar for home and sleep laboratory set-up, resulting in a very good reproducibility (intraclass correlation coefficient of 0.85). No differences in total sleep time and sleep architecture were observed in both set-up protocols. Except for sleep duration, which was longer in the first H-PSG test, we did not observe any first-night effect during the first H-PSG.
Conclusion:
The present study demonstrates that hospital hook-up is as effective as home hook-up for home-unattended polysomnography, and that feasibility and repeatability of H-PSG are very good.
More Related Videos
04:09Prospective, Randomized, and Controlled Study of a Human Umbilical Cord Mesenchymal Stem Cell Injection for Treating Diabetic Foot Ulcers
Published on: March 3, 2023
09:52Setting Up a Stroke Team Algorithm and Conducting Simulation-based Training in the Emergency Department - A Practical Guide
Published on: January 15, 2017
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Hospitals-II
Nurses that work in...
Hospitals-I
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...