Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Viscoelastic Modeling of Optic Nerve Head Biomechanics: Effects of Intraocular and Cerebrospinal Fluid Pressure.

Biocybernetics and biomedical engineering·2025
Same author

Continuous Wireless Telemetric Measurement of Intraocular Pressure (IOP), Ocular Perfusion Pressure (OPP), and Cerebrospinal Fluid Pressure (CSFP) in Nonhuman Primates (NHPs).

Methods in molecular biology (Clifton, N.J.)·2024
Same author

Morphological and biomechanical analyses of the human healthy and glaucomatous aqueous outflow pathway: Imaging-to-modeling.

Computer methods and programs in biomedicine·2023
Same author

Modeling the Endothelial Glycocalyx Layer in the Human Conventional Aqueous Outflow Pathway.

Cells·2022
Same author

The Effect of Intraocular Pressure Load Boundary on the Biomechanics of the Human Conventional Aqueous Outflow Pathway.

Bioengineering (Basel, Switzerland)·2022
Same author

Viscoelastic Biomechanical Properties of the Conventional Aqueous Outflow Pathway Tissues in Healthy and Glaucoma Human Eyes.

Journal of clinical medicine·2022

Related Experiment Video

Updated: Apr 6, 2026

A MRI-Based Toolbox for Neurosurgical Planning in Nonhuman Primates
08:41

A MRI-Based Toolbox for Neurosurgical Planning in Nonhuman Primates

Published on: July 17, 2020

5.5K

IOP telemetry in the nonhuman primate.

J Crawford Downs1

  • 1Department of Ophthalmology, University of Alabama at Birmingham School of Medicine, Birmingham, AL, USA.

Experimental Eye Research
|July 29, 2015
PubMed
Summary

Continuous intraocular pressure (IOP) monitoring in nonhuman primates (NHPs) using telemetry systems is crucial. This technology helps understand how IOP fluctuations contribute to glaucoma development and progression.

Area of Science:

  • Ophthalmology
  • Biomedical Engineering
  • Veterinary Science

Background:

  • Intraocular pressure (IOP) fluctuations over time are increasingly implicated in glaucoma pathogenesis.
  • Nonhuman primates (NHPs) serve as a valuable model for studying ocular diseases like glaucoma.
  • Understanding dynamic IOP changes is essential for assessing glaucoma risk and progression.

Purpose of the Study:

  • To review continuous IOP monitoring techniques in NHPs using telemetry.
  • To contextualize IOP dynamics within glaucoma pathogenesis, considering factors like age, race, and disease.
  • To evaluate current and emerging methods for continuous IOP measurement in NHPs.

Main Methods:

  • Literature review of studies employing IOP telemetry in NHPs.
Keywords:
BiomechanicsGlaucomaIOPNonhuman primateTelemetry

More Related Videos

Author Spotlight: Streamlined Brain and Skull Modeling for Enhanced Neurosurgical Planning in NHP Research
06:33

Author Spotlight: Streamlined Brain and Skull Modeling for Enhanced Neurosurgical Planning in NHP Research

Published on: February 9, 2024

1.9K
Convection Enhanced Delivery of Optogenetic Adeno-associated Viral Vector to the Cortex of Rhesus Macaque Under Guidance of Online MRI Images
08:52

Convection Enhanced Delivery of Optogenetic Adeno-associated Viral Vector to the Cortex of Rhesus Macaque Under Guidance of Online MRI Images

Published on: May 23, 2019

7.5K

Related Experiment Videos

Last Updated: Apr 6, 2026

A MRI-Based Toolbox for Neurosurgical Planning in Nonhuman Primates
08:41

A MRI-Based Toolbox for Neurosurgical Planning in Nonhuman Primates

Published on: July 17, 2020

5.5K
Author Spotlight: Streamlined Brain and Skull Modeling for Enhanced Neurosurgical Planning in NHP Research
06:33

Author Spotlight: Streamlined Brain and Skull Modeling for Enhanced Neurosurgical Planning in NHP Research

Published on: February 9, 2024

1.9K
Convection Enhanced Delivery of Optogenetic Adeno-associated Viral Vector to the Cortex of Rhesus Macaque Under Guidance of Online MRI Images
08:52

Convection Enhanced Delivery of Optogenetic Adeno-associated Viral Vector to the Cortex of Rhesus Macaque Under Guidance of Online MRI Images

Published on: May 23, 2019

7.5K
  • Analysis of published data on continuous IOP measurements in NHPs.
  • Assessment of the strengths, weaknesses, and limitations of various telemetry approaches.
  • Main Results:

    • Limited but growing body of research exists on NHP IOP telemetry.
    • Telemetry systems offer continuous IOP data, providing insights into diurnal and other fluctuations.
    • Various technological approaches have been utilized, each with specific advantages and drawbacks.

    Conclusions:

    • Continuous IOP monitoring in NHPs is a promising area for glaucoma research.
    • Telemetry data can elucidate the role of IOP dynamics in glaucoma susceptibility and progression.
    • Further development and validation of NHP IOP telemetry systems are warranted.