Related Experiment Video
Updated: Apr 6, 2026

Chronic Transcranial Electrical Stimulation and Intracortical Recording in Rats
Published on: May 11, 2018
Reduction of epileptiform activity through local valproate-implants in a rat neocortical epilepsy model
Michael P Rassner1, Jonas M Hebel2, Dirk-Matthias Altenmüller3
1Section of Clinical Neuropharmacology, Department of Neurosurgery, Neurocenter, University Medical Center, Albert-Ludwigs-University, Breisacher Straße 64, 79106 Freiburg im Breisgau, Germany.
Purpose:
Pharmacotherapy of epilepsies is limited due to low concentrations at epileptogenic foci, side effects of high systemic doses and that some potentially efficient substances do not pass the blood-brain barrier. To overcome these limitations, we tested the efficacy of local valproate (VPA)-containing polymer implants in a model of necocortical injected tetanus toxin (TeT) in the rat.
Methods:
Tetanus toxin was injected intracortically and cobalt (II) chloride (CoCl2) was applied on the cortical surface. Video-electrocorticography recordings with intracortical electrodes were performed. VPA-containing polymers were implanted above the cortical focus. Antiepileptic effects were evaluated as reductions of epileptiform potentials (EPs) per hour in comparison to saline (NaCl)-containing polymer implants.
Results:
Triple 50ng TeT injections plus CoCl2 application (20/10mg) showed consistent EPs. NaCl-implanted animals (n=6) showed a mean of 10.5EPs/h after the first week, the EP frequency increased to 53.5EPs/h after the second week. VPA-implant animals (n=5) showed a reduction in EP frequency from 71.6 to 4.8EPs/h after the second week. The EP frequency after the second week was higher in the NaCl-implanted animals than in the VPA-implanted (p=0.0303). The mean EPs/h increase in NaCl-implanted rats (+42.9EPs/h) was different (p=0.0087) from the mean EPs/h decrease in VPA-implanted rats (-66.8EPs/h).
Conclusion:
Despite former publications no clear seizures could be reproduced but it was possible to establish focal EPs, which proved to be a reliable marker for epileptic activity. Local antiepileptic therapy with VPA has shown efficacy in decreasing EP frequency.
More Related Videos
09:29Preparation and Implantation of Electrodes for Electrically Kindling VGAT-Cre Mice to Generate a Model for Temporal Lobe Epilepsy
Published on: August 17, 2021
09:07Electroconvulsive Seizures in Rats and Fractionation of Their Hippocampi to Examine Seizure-induced Changes in Postsynaptic Density Proteins
Published on: August 15, 2017