Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Dosimetric effect due to the motion during deep inspiration breath hold for left-sided breast cancer radiotherapy
Xiaoli Tang1, Tim Cullip, John Dooley
1Memorial Sloan Kettering Cancer Center. xiaoli.tang@gmail.com.
Abstract:
Deep inspiration breath-hold (DIBH) radiotherapy for left-sided breast cancer can reduce cardiac exposure and internal motion. We modified our in-house treatment planning system (TPS) to retrospectively analyze breath-hold motion log files to calculate the dosimetric effect of the motion during breath hold. Thirty left-sided supine DIBH breast patients treated using AlignRT were studied. Breath-hold motion was recorded — three translational and three rotational displacements of the treatment surface — the Real Time Deltas (RTD). The corresponding delivered dose was estimated using the beam-on portions of the RTDs. Each motion was used to calculate dose, and the final estimated dose was the equally weighted average of the multiple resultant doses. Ten of thirty patients had internal mammary nodes (IMN) purposefully included in the tangential fields, and we evaluated the percentage of IMN covered by 40 Gy. The planned and delivered heart mean dose, lungs V20 (volume of the lungs receiving > 20 Gy), percentage of IMN covered by 40 Gy, and IMN mean dose were compared. The averaged mean and standard deviation of the beam-on portions of the absolute RTDs were 0.81 ± 1.29 mm, 0.68 ± 0.85mm, 0.76 ± 0.85 mm, 0.96° ± 0.49°, 0.93° ± 0.43°, and 1.03° ± 0.50°, for vertical, longitudinal, lateral, yaw, roll, and pitch, respectively. The averaged planned and delivered mean heart dose were 99 and 101 cGy. Lungs V20 were 6.59% and 6.74%. IMN 40 Gy coverage was 83% and 77%, and mean IMN dose was 4642 and 4518 cGy. The averaged mean motion during DIBH was smaller than 1 mm and 1°, which reflects the relative reproducibility of the patient breath hold. On average, the mean heart dose and lungs V20 were reasonably close to what have been planned. IMN 40 Gy coverage might be modestly reduced for certain cases.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: