[New aspects from legislation, guidelines and safety standards for MRI]
M Mühlenweg1, G Schaefers, S Trattnig
1Institut für Radiologie, Krankenhaus Martha-Maria Halle-Dölau, Röntgenstr. 1, 06120, Halle (Saale), Deutschland, martin.muehlenweg@web.de.
Abstract:
Many aspects of magnetic resonance (MR) operation are not directly regulated by law but in standards, guidelines and the operating instructions of the MR scanner. The mandatory contents of the operating instructions are regulated in a central standard of the International Electrotechnical Commission (IEC) 60601-2-33. In this standard, the application of static magnetic fields in MRI up to 8 Tesla (T) in the clinical routine (first level controlled mode) has recently been approved. Furthermore, the equally necessary CE certification of ultra-high field scanners (7-8 T) in Europe is expected for future devices. The existing installations will not be automatically certified but will retain their experimental status. The current extension of IEC 60601-2-33 introduces a new add-on option, the so-called fixed parameter option (FPO). This option might also be switched on in addition to the established operating modes and defines a fixed device constellation and certain parameters of the energy output of MR scanners designed to simplify the testing of patients with implants in the future.The employment of pregnant workers in an MRI environment is still not generally regulated in Europe. In parts of Germany and Austria pregnant and lactating employees were prohibited from working in the MR control zone (0.5 mT) in 2014. This is based on the mostly unresolved question of the applicability of limits for employees (exposure of extremities to static magnetic fields up to 8 T allowed) or the thresholds for the general population (maximum 400 mT). According to the European Society of Urogenital Radiology (ESUR), the discarding of breast milk after i.v. administration of gadolinium-based contrast agents in the case of a breastfeeding woman is only recommended when using contrast agents in the nephrogenic systemic fibrosis (NSF) high-risk category.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT