Related Experiment Video
Updated: Apr 6, 2026

Construction and Implantation of a Microinfusion System for Sustained Delivery of Neuroactive Agents.
Published on: March 17, 2008
In Vitro and In Vivo Performance of a Pre-Filled, Electrochemically-Actuated Infusion System
Assaf Shaked1, Ella Tenenbaum-Koren2, Jacob Atsmon3
1SteadyMed Ltd., Rehovot, Israel.
Purpose:
A novel infusion system (PatchPump®) has been developed using an electrochemical actuator and a semi-flexible container to deliver liquid formulations through an infusion set. In vitro studies characterized pump performance, and clinical studies evaluated functionality and pharmacokinetic (PK) performance in humans.
Methods:
Total delivered volume and flow rate accuracy were determined in vitro by real-time gravimetric analysis. Functionality was evaluated in vivo using prototype devices delivering saline for 18 h in a clinical study enrolling 10 healthy volunteers. A second clinical study examined the PK of delivering treprostinil at an average dose of 2.3 ng/kg/min to 5 healthy volunteers for 18 h.
Results:
Relative to a design target of 0.042 mL/hr, the average flow rate of 23 PatchPumps operating for 48 continuous hours was 0.043 ± 0.007 mL/hr as tested in vitro. In vivo functionality was confirmed by complete infusion of saline for the entire duration with only mild and transient adverse effects. PK results with an infusion rate of 0.045 mL/hr of treprostinil resulted in mean Css of 297 pg/mL and T1/2 of 4.44 h, comparable to prior studies using conventional infusion pumps.
Conclusions:
The results of these studies demonstrate a successful proof-of-concept for the PatchPump technology.
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions