Low dose CT of the lumbar spine compared with radiography: a study on image quality with implications for clinical
Muhammed Alshamari1, Mats Geijer2, Eva Norrman3
1Department of Radiology, Faculty of Medicine and Health, Örebro University, Örebro, Sweden muhammed.alshamari@regionorebrolan.se.
Background:
Lumbar spine radiography is often performed instead of CT for radiation dose concerns.
Purpose:
To compare image quality and diagnostic information from low dose lumbar spine CT at an effective dose of about 1 mSv with lumbar spine radiography.
Material And Methods:
Fifty-one patients were examined by both methods. Five reviewers scored all examinations on eight image quality criteria using a five-graded scale and also assessed three common pathologic changes.
Results:
Low dose CT scored better than radiography on the following: sharp reproduction of disc profile and vertebral end-plates (odds ratio [OR], 1.8; 95% confidence interval [CI], 1.3-2.5), intervertebral foramina and pedicles (OR, 4.3; 95% CI, 3.1-5.9), intervertebral joints (OR, 139; 95% CI, 59-326), spinous and transverse processes (OR, 7.0; 95% CI, 4.3-11.2), sacro-iliac joints (OR, 4.2; 95% CI, 3.2-5.7), reproduction of the adjacent soft tissues (OR, 2.9; 95% CI, 2.1-4.0), and absence of any obscuring superimposed gastrointestinal gas and contents (OR, 188; 95% CI, 66-539). Radiography scored better on sharp reproduction of cortical and trabecular bone (OR, 0.3; 95% CI, 0.2-0.4). The reviewers visualized disk degeneration, spondylosis/diffuse idiopathic skeletal hyperostosis (DISH) and intervertebral joint osteoarthritis more clearly and were more certain with low dose CT. Mean time to review low dose CT was 204 s (95% CI, 194-214 s.), radiography 152 s (95% CI, 146-158 s.). The effective dose for low dose CT was 1.0-1.1 mSv, for radiography 0.7 mSv.
Conclusion:
Low dose lumbar spine CT at about 1 mSv has superior image quality to lumbar spine radiography with more anatomical and diagnostic information.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
03:14Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT