Related Experiment Video
Updated: Apr 6, 2026

The Caco-2 Cell Bioassay for Measurement of Food Iron Bioavailability
Published on: April 28, 2022
Can serum isotope levels accurately measure intestinal calcium absorption compared to gold-standard methods?
Andrew P Vreede1, Andrea N Jones2, Karen E Hansen3
1Department of Medicine, University of Wisconsin School of Medicine & Public Health, Suite 4124 MFCB, 1685 Highland Avenue, Madison, WI, 53705-2281, USA. AVreede@uwhealth.org.
Background:
Low fractional calcium absorption (FCA) contributes to osteoporosis but is not measured clinically, as the gold-standard method requires administration of two calcium tracers and a subsequent 24-h urine collection. We evaluated alternate methods to measure FCA, compared to the gold standard method.
Methods:
We administered two stable calcium isotope tracers (~8 mg oral (44)Ca and ~3 mg intravenous (42)Ca) with breakfast to 20 fasting post-menopausal women (Cohort 1) 59 ± 7 years old with vitamin D insufficiency. We measured subsequent calcium isotope concentrations in 24-h urine samples and serum collected 1, 3 and 5 h post tracer administration during an inpatient research stay. We assessed the candidate serum estimates in a second cohort of 9 women with similar characteristics. Methods of measuring FCA were compared using correlation coefficients and Bland-Altman tests.
Results:
FCA estimated from a 3-h serum sample correlated highest with the levels from the 24-h urine collection (ρ 0.78, p < 0.001), but explained only 58 % of the variance in FCA. The total variance explained by 3-h estimates improved to 61 % with incorporation of glomerular filtration rate (GFR). FCA estimates from the 3-h serum measurement were assessed in a second group of nine women (Cohort 2) 60 ± 7 years old. In this cohort, however, FCA estimated by 3-h serum isotope levels did not correlate with gold-standard FCA measurements, whether determined with (ρ 0.02, p = 0.97) or without GFR values (ρ 0.03, p = 0.93). By contrast, FCA in Cohort 2 correlated best with 5-h serum isotope levels (ρ 0.75, p = 0.02).
Conclusions:
We conclude that serum isotope levels correlate with true fractional calcium absorption, but do not reliably estimate FCA when analyzed using Bland-Altman tests, compared to gold-standard methods.
Trial Registration:
ClinicalTrials.gov.Identifier: NCT00933244.
Related Concept Videos
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Serum Laboratory Studies, Stool Test, Breath Test

