Related Experiment Video For Raman spectroscopy
Updated: Apr 6, 2026

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Real-time Raman spectroscopy for automatic in vivo skin cancer detection: an independent validation
Jianhua Zhao1,2, Harvey Lui1,2, Sunil Kalia1
1Photomedicine Institute, Department of Dermatology and Skin Science, University of British Columbia and Vancouver Coastal Health Research Institute, 835 West 10th Ave, Vancouver, BC, V5Z 4E8, Canada.
Abstract:
In a recent study, we have demonstrated that real-time Raman spectroscopy could be used for skin cancer diagnosis. As a translational study, the objective of this study is to validate previous findings through a completely independent clinical test. In total, 645 confirmed cases were included in the analysis, including a cohort of 518 cases from a previous study, and an independent cohort of 127 new cases. Multi-variant statistical data analyses including principal component with general discriminant analysis (PC-GDA) and partial least squares (PLS) were used separately for lesion classification, which generated similar results. When the previous cohort (n = 518) was used as training and the new cohort (n = 127) was used as testing, the area under the receiver operating characteristic curve (ROC AUC) was found to be 0.889 (95 % CI 0.834-0.944; PLS); when the two cohorts were combined, the ROC AUC was 0.894 (95 % CI 0.870-0.918; PLS) with the narrowest confidence intervals. Both analyses were comparable to the previous findings, where the ROC AUC was 0.896 (95 % CI 0.846-0.946; PLS). The independent study validates that real-time Raman spectroscopy could be used for automatic in vivo skin cancer diagnosis with good accuracy.
More Related Videos
09:37Combining Reflectance Confocal Microscopy with Optical Coherence Tomography for Noninvasive Diagnosis of Skin Cancers via Image Acquisition
Published on: August 18, 2022
08:05Detection and Isolation of Cancer in Prostate Biopsies Using Stimulated Raman Histology and Artificial Intelligence
Published on: June 10, 2025
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Skin Cancer
Basal Cell Carcinoma (BCC): BCC is the most common type of skin cancer, accounting for about 80% of cases. It typically develops in...