Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Benjamin Nelms1, Cassandra Stambaugh2, Dylan Hunt3

  • 1Canis Lupus LLC, Merrimac, Wisconsin 53561.

Medical Physics
|August 3, 2015
PubMed
Summary

This study introduces a new, software-independent method to evaluate dose-volume histogram (DVH) accuracy. PlanIQ demonstrated higher accuracy than Pinnacle, highlighting the importance of robust DVH calculation in radiation therapy.

Related Concept Videos

Accuracy, limits, and approximation01:28

Accuracy, limits, and approximation

Accuracy, limits, and approximations are common in many fields, especially in engineering calculations. These concepts are imperative for ensuring that a given value is as close as possible to its true value.
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
1.4K
Volume of Distribution01:20

Volume of Distribution

The apparent volume of distribution (Vd) is a crucial pharmacokinetic parameter representing the hypothetical body fluid volume into which a drug disperses. It is calculated based on the total amount of drug in the body (estimated from the administered dose and bioavailability) divided by the plasma drug concentration. The total amount of drug in the body does not directly refer to the dose given but is derived by accounting for absorption, distribution, metabolism, and excretion processes.
1.8K
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
1.0K
Standard Deviation of Calculated Results01:14

Standard Deviation of Calculated Results

Standard deviation measures the spread of data around the mean value. Many large data sets follow a Gaussian distribution, also known as a normal distribution. This distribution is bell-shaped curved, with the most frequently observed value (mean or central value) in the middle. The farther away from the central value, the greater the deviation from the central value, and the lower the frequency.
A broad Gaussian distribution curve has a wider standard deviation, representing a data set with...
9.4K
Henderson-Hasselbalch Equation02:48

Henderson-Hasselbalch Equation

The ionization-constant expression for a solution of a weak acid can be written as:
79.7K
Bernoulli's Equation: Problem Solving01:16

Bernoulli's Equation: Problem Solving

A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
2.1K