Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Apr 6, 2026

Author Spotlight: Multimodal Imaging Strategies for Optimizing Drug Delivery and Early Detection in Glioblastoma Treatment
07:25

Author Spotlight: Multimodal Imaging Strategies for Optimizing Drug Delivery and Early Detection in Glioblastoma Treatment

Published on: March 1, 2024

3.2K

Real-Time MRI-Guided Catheter Tracking Using Hyperpolarized Silicon Particles.

Nicholas Whiting1, Jingzhe Hu2, Jay V Shah3

  • 1Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX 77030.

Scientific Reports
|August 5, 2015
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reprogramming of Cellular Plasticity via ETS and MYC Core-regulatory Circuits During Response to MAPK Inhibition in BRAF-mutant Colorectal Cancer.

Clinical cancer research : an official journal of the American Association for Cancer Research·2026
Same author

Platelets: the next-generation ovarian cancer biomarker?

Trends in cancer·2026
Same author

Multiscale decomposition and fuzzy-rule attention: A transferable cross-basin framework for long-term water quality forecasting.

Water research·2026
Same author

Implemented one-pot two step fully automated synthesis of [<sup>18</sup>F]FPIA for metabolic imaging applications.

Nuclear medicine and biology·2026
Same author

SABRE Acethydrazide as a Co-Substrate Agent for Quantitative Analysis of Submicromolar N-Heterocyclic Compounds Using Parahydrogen Hyperpolarization.

Analytical chemistry·2026
Same author

Antibody-Protein L Functionalized Microparticles for Detection of Surface Markers in Heterogeneous Colorectal Lesions.

bioRxiv : the preprint server for biology·2025

This study introduces a new way to track medical catheters during surgery using magnetic resonance imaging instead of traditional X-rays. By attaching special silicon particles that glow brightly in scans, doctors can see the catheter's position clearly without exposing patients to harmful radiation.

Area of Science:

  • Medical imaging research within hyperpolarized silicon particles technology
  • Endovascular intervention diagnostics

Background:

Standard endovascular procedures rely heavily on X-ray fluoroscopy to visualize surgical tools inside the body. This approach exposes both patients and medical staff to ionizing radiation throughout the intervention. Magnetic resonance imaging offers a safer alternative by providing detailed three-dimensional views of internal structures. However, tracking devices within this environment remains a significant technical challenge for clinicians. No prior work had resolved the need for high-contrast, non-toxic markers compatible with magnetic resonance systems. That uncertainty drove the development of specialized agents capable of maintaining visibility over long durations. This paper addresses the gap by utilizing unique particles that provide clear signals without background interference. Prior research has shown that signal enhancement techniques can improve the sensitivity of various imaging probes.

Purpose Of The Study:

The study aims to introduce a magnetic resonance-guided catheter tracking method using hyperpolarized silicon particles. This research addresses the reliance on X-ray fluoroscopy for visualizing surgical tools during endovascular interventions. The authors seek to develop an approach that allows for three-dimensional imaging of the tissue interface. A major motivation is to eliminate the exposure of patients and clinicians to ionizing radiation. The team intends to provide a zero-background, positive contrast agent for real-time navigation. They aim to demonstrate that these particles can maintain signal enhancement for extended durations. This work addresses the technical challenges associated with tracking devices in magnetic resonance environments. The researchers hope to establish a proof-of-concept that could eventually supplement current clinical imaging standards.

Keywords:
magnetic resonance imagingcatheter navigationpositive contrast agentionizing radiation reduction

Frequently Asked Questions

The researchers propose using hyperpolarized silicon particles as positive contrast agents. These markers provide a zero-background signal, allowing for precise localization of the catheter tip during navigation through vasculature. Unlike traditional methods, this approach avoids the use of ionizing radiation entirely.

The team utilizes low-temperature, solid-state dynamic nuclear polarization to generate the signal. This process significantly boosts the magnetic resonance visibility of the silicon particles, enabling them to be detected clearly against the surrounding tissue environment.

The particles must be affixed to the tip of standard medical-grade catheters to ensure accurate tracking. This placement is necessary to monitor the device's passage through distal and temporal points within phantoms and live animal models.

More Related Videos

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
09:13

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

Published on: April 21, 2013

28.7K
Magnetic Resonance-Guided Stereotaxy for Infusions to the Pig Brain
08:23

Magnetic Resonance-Guided Stereotaxy for Infusions to the Pig Brain

Published on: March 31, 2023

3.3K

Related Experiment Videos

Last Updated: Apr 6, 2026

Author Spotlight: Multimodal Imaging Strategies for Optimizing Drug Delivery and Early Detection in Glioblastoma Treatment
07:25

Author Spotlight: Multimodal Imaging Strategies for Optimizing Drug Delivery and Early Detection in Glioblastoma Treatment

Published on: March 1, 2024

3.2K
Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
09:13

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

Published on: April 21, 2013

28.7K
Magnetic Resonance-Guided Stereotaxy for Infusions to the Pig Brain
08:23

Magnetic Resonance-Guided Stereotaxy for Infusions to the Pig Brain

Published on: March 31, 2023

3.3K

Main Methods:

The researchers designed a proof-of-concept study to evaluate a novel magnetic resonance-guided tracking approach. They utilized low-temperature, solid-state dynamic nuclear polarization to create the signal-enhanced markers. These particles were then securely attached to the tips of standard medical-grade catheters. The team conducted experiments using both phantoms and live mouse models to test navigation accuracy. They monitored the passage of the devices through various distal and temporal points. The approach focused on achieving high-contrast visibility without relying on traditional radiation-based imaging tools. Data collection involved real-time tracking during simulated and biological interventions. This systematic evaluation confirmed the feasibility of the proposed tracking strategy in diverse settings.

Main Results:

The strongest finding indicates that the particles provide a zero-background, positive contrast signal for effective catheter visualization. The enhanced signal remains detectable for at least forty minutes, supporting extended surgical procedures. Testing in phantoms and live mouse models successfully demonstrated accurate tracking through defined distal and temporal points. This performance confirms the potential of the particles to serve as reliable markers in magnetic resonance environments. The results show that the signal generation process is robust enough for practical application. No ionizing radiation was required to achieve these tracking outcomes during the experiments. The data support the viability of this method as a supplement to existing imaging standards. These findings establish a baseline for future developments in radiation-free endovascular navigation.

Conclusions:

The authors demonstrate that these particles function as effective positive contrast agents for tracking. This method provides a clear visual signal without the background noise typically associated with other markers. The researchers suggest that this approach could eventually serve as a viable alternative to X-ray fluoroscopy. By eliminating ionizing radiation, the technique offers a safer environment for both patients and the clinical team. The study confirms that the particles remain visible for at least forty minutes during experimental procedures. Future efforts will focus on refining the integration of these markers with standard medical-grade catheters. The team proposes that this technology might supplement existing magnetic resonance-guided tracking methods in clinical settings. These findings represent a successful proof-of-concept for real-time navigation during endovascular interventions.

The researchers employ phantoms and live mouse models to validate the tracking capabilities. These data sources allow the team to assess the performance of the particles in both controlled environments and complex biological systems.

The particles retain their enhanced signal for at least forty minutes. This duration is sufficient for performing extended imaging experiments, providing a stable window for clinicians to navigate the catheter through the vasculature.

The authors suggest that this method could eventually supplement existing X-ray fluoroscopy. By providing a radiation-free alternative, the researchers propose that this technology may improve safety profiles for both the patient and the surgical staff.