Related Experiment Video
Updated: Apr 5, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Biodistribution and estimation of radiation-absorbed doses in humans for 13N-ammonia PET
Chang Yi1, Donglan Yu2, Xinchong Shi1
1Department of Nuclear Medicine, The First Affiliated Hospital of Sun Yat-Sen University, 58#, Zhongshan Er Road, Guangzhou, 510080, China.
Objective:
To evaluate the biodistribution of radiation-absorbed doses of (13)N-ammonia in healthy people.
Methods:
Five healthy human subjects underwent whole-body PET and CT scans after injection of 555-740 MBq of (13)N-ammonia. Five serial dynamic emission scans in each healthy volunteer were acquired. Regions of interest were drawn on the CT image and transferred to the corresponding transverse PET slice. Estimates of the radiation-absorbed doses were calculated using the medical internal radiation dosimetry method.
Results:
The highest concentrations of (13)N-ammonia were found in the heart and liver, followed by pancreas, brain, spleen and stomach. The highest absorbed organ doses were to the heart wall (7.14E-03 ± 3.63E-03 mGy/MBq) and kidneys (6.02E-03 ± 3.53E-03 mGy/MBq). The effective dose (ED) was 6.58E-03 ± 1.23E-03 mSv/MBq.
Conclusions:
With these new estimates for (13)N-ammonia dosimetry, the results for Chinese people were not appreciably different from those of the previous study performed with old devices. As one of the most important myocardial perfusion PET tracers, the whole-body (13)N-ammonia PET appears to be safe for humans, yielding a relatively modest radiation burden that would allow multiple PET studies on the same subject per year.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...