Five algorithms that calculate cardiac output from the arterial waveform: a comparison with Doppler ultrasound
J Zhang1, L A H Critchley2, L Huang3
1Department of Anesthesiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Background:
Different mathematical approaches are used to calculate arterial pulse pressure wave analysis (PPWA) cardiac output. The CardioQ-Combi is a research oesophageal Doppler (COODM) monitor that includes these five fundamental PPWA algorithms. We compared these PPWA cardiac output readings to COODM and suprasternal USCOM Doppler (COUS) over a range of cardiac output values induced by dopamine infusion in patients undergoing major surgery. USCOM acted as a control.
Methods:
Serial sets of cardiac output data were recorded at regular intervals as cardiac output increased. Formulae included: cardiac output calculated form systemic vascular resistance (COMAP), pulse pressure (COPP), Liljestrand-Zander formula (COLZ), alternating current power (COAC) and systolic area with Kouchoukos correction (COSA). The reference method for comparisons was COODM. Statistical methods included: Scatter plots (correlation), Bland-Altman (agreement) and concordance (trending) and polar (trending).
Results:
From 20 patients 255 sets of cardiac output comparative data were collected. Mean cardiac output for each method ranged between 5.0 and 5.5 litre min(-1). For comparisons between COUS and the five PPWA algorithms with COODM: Correlation was best with COUS (R(2)=0.81) followed by COLZ (R(2)=0.72). Bias ranged between 0.1 and 0.5 litre min(-1). Percentage error was lowest with COUS (26.4%) followed by COLZ (35.2%), others (40.7 to 56.3%). Concordance was best with COUS (92%), followed by COLZ (71%), others (64 to 66%). Polar analysis (mean(standard deviation)) were best with COUS (-2.7 (21.1)), followed by COLZ (+4.7 (26.6).
Conclusions:
The Liljestrand-Zander PPWA formula was most reliable compared with oesophageal Doppler in major surgical patients under general anaesthesia, but not better than USCOM.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
06:10Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...