Accuracy of inhaled agent usage displays of automated target control anesthesia machines
Alexander Dehouwer1, Rik Carette1, Simon De Ridder1
1Department of Anesthesiology, Intensive Care and Pain Therapy, OLV Hospital, Moorselbaan 164, 9300, Aalst, Belgium.
Abstract:
Automated low flow anesthesia machines report how much inhaled anesthetic agent has been used for each anesthetic. We compared these reported values with the amount of agent that had disappeared by weighing the vaporizer/injectors before and after each anesthetic. The vaporizers/injectors of the Aisys, Zeus and FLOW-i were weighed with a high precision weighing scale before and after anesthesia with either desflurane in O2/air or sevoflurane in O2/N2O. These values were compared with the values reported by the cumulative agent use display tools of the respective anesthesia machines using a linear curve fit. Twenty-five measurements were performed in each group, except for the sevoflurane data with the Aisys that were available from another study (87 pairs). We also determined the amount lost by inserting and removing the vaporizers/injectors or by performing a machine checkout, corrected the measured amounts for these artifacts and repeated the linear fits. The average amount of sevoflurane and desflurane wasted by inserting and removing the cassette for the Aisys, Zeus, and FLOW-i were 0.21, 0.12, and 0.04 mL and 0.12, 0.61, and 1.13 mL liquid agent, respectively. The average amount of sevoflurane and desflurane wasted by the machine checkout with the Aisys, Zeus, and FLOW-i were 1.78, 0.21, and 1.67 mL and 2.39, 0.67, and 4.19 mL, respectively. Performance error of the displayed amount of agent use remained within 10 % of the weighed amount, expect for amounts less than 3 mL sevofurane with the FLOW-i and less than 20 mL desflurane with the Aisys and FLOW-i. Cumulative agent usage displayed by the Aisys, Zeus, and FLOW-i is within 10 % of the measured consumption, except for low consumption cases (<3 mL sevoflurane, <20 mL desflurane). The differences may be due to either measurement error or cumulative agent display error. The current results can help the researchers decide whether the displayed amounts are accurate enough for their study purposes. The extent to which these discrepancies differ between different units of the same machine remains unstudied.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Inhalational Anesthetics: Overview
Parenteral Anesthetics: Overview
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Inhaled Medications
Local Anesthetics: Common Agents and Their Applications
Cocaine is an ester of benzoic acid and methylecgogine. It is used to anesthetize and vasoconstrict locally. Currently, it is used primarily for topical applications. It is beneficial for surgeries on the upper respiratory tract, providing anesthesia and shrinking the mucosa. Cocaine in the form of cocaine hydrochloride is...