Published on: January 17, 2020
A selective determination of copper ions in water samples based on the fluorescence quenching of thiol-capped CdTe
Piyaluk Nurerk1,2, Proespichaya Kanatharana1,2, Opas Bunkoed1,2
1Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla, 90112, Thailand.
Abstract:
CdTe quantum dots (QDs) capped with different stabilizers, i.e. thioglycolic acid (TGA), 3-mercaptopropionic acid (MPA) and glutathione (GSH) were investigated as fluorescent probes for the determination of Cu(2+). The stabilizer was shown to play an important role in both the sensitivity and selectivity for the determination of Cu(2+). TGA-capped CdTe QDs showed the highest sensitivity, followed by the MPA and GSH-capped CdTe QDs, respectively. The TGA- and MPA-capped CdTe QDs were not selective for Cu(2+) that was affected by Ag(+). The GSH-capped CdTe QDs were insensitive to Ag(+) and were used to determine Cu(2+) in water samples. Under optimal conditions, quenching of the fluorescence intensity (F0/F) increased linearly with the concentration of Cu(2+) over a range of 0.10-4.0 µg/mL and the detection limit was 0.06 µg/mL. The developed method was successfully applied to the determination of Cu(2+) in water samples. Good recoveries of 93-104%, with a relative standard deviation of < 6% demonstrated that the developed simple method was accurate and reliable. The quenching mechanisms were also described.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
11:38Quantifying the Binding Interactions Between CuII and Peptide Residues in the Presence and Absence of Chromophores
Published on: April 5, 2022
Related Concept Videos
Extraction: Advanced Methods
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Controlled-Current Coulometry: Overview
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...