Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

[Pupillographic perimetry using the "Octopus"].

E Alexandridis, H Krastel

    Fortschritte Der Ophthalmologie : Zeitschrift Der Deutschen Ophthalmologischen Gesellschaft
    |January 1, 1989
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    [Neurovascular conflict as a rare cause of internal and external ophthalmoplegia].

    Die Ophthalmologie·2024
    Same author

    Randomised clinical study: comparison of acceptability, patient tolerance, cardiac stress and endoscopic views in transnasal and transoral endoscopy under local anaesthetic.

    Alimentary pharmacology & therapeutics·2014
    Same author

    [Quality demands on the assessment of colour vision].

    Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·2009
    Same author

    [Photopic contrast sensitivity. Local contrast perception].

    Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·2008
    Same author

    [Determination of visual function in legal assessment].

    Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·2007
    Same author

    Improved survival of patients presenting with acute variceal bleeding. Prognostic indicators of short- and long-term mortality.

    Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver·2006
    Same journal

    [Standardized determination of pressure tolerance of the optic nerve head].

    Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·1991
    Same journal

    [Acute circulatory disorders of the eye. Clinical findings and results of Doppler sonography of the internal carotid artery].

    Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·1991
    Same journal

    [Subclinical eye movements as an indicator for inheritance of congenital nystagmus and central nervous system disease].

    Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·1991
    Same journal

    [Physiologic and pathologic rebound nystagmus. Description and comparison].

    Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·1991
    Same journal

    [Foundation of a linear trichromatic transfer theory on color judgment of unsaturated colors].

    Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·1991
    Same journal

    [Discrimination difficulties--expression of disordered relative localization?].

    Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·1991
    See all related articles

    This study introduces a novel pupilloperimetric program for the Octopus 2000 perimeter, integrating infrared videopupillography to objectively assess visual field thresholds. This method enhances diagnostic accuracy by analyzing pupil responses, reducing potential malingering.

    Area of Science:

    • Ophthalmology
    • Neuroscience
    • Medical Technology

    Context:

    • Standard visual field testing relies on subjective patient responses, which can be unreliable.
    • Pupil light response (PLR) offers an objective measure of visual pathway function.
    • Integrating PLR with perimetry can improve the accuracy of visual field assessment.

    Purpose:

    • To develop and evaluate a pupilloperimetric program for the Octopus 2000 perimeter.
    • To combine infrared videopupillography with computerized perimetry for simultaneous fixation control and PLR recording.
    • To establish a method for objective visual field threshold determination using pupillary responses.

    Summary:

    • A Sargon-based pupilloperimetric program was developed for the Octopus 2000, utilizing infrared videopupillography to record direct pupil light responses.

    Related Experiment Videos

  • The system digitally processes pupil video at 25 cps, displaying responses on an oscilloscope and via penwriter printout for immediate analysis.
  • Thresholds are determined by examiner assessment of pupil responses at 12 visual field locations, offering an objective alternative to subjective patient reports.
  • Impact:

    • This pupilloperimetric approach minimizes the influence of subjective patient reporting, potentially identifying malingering.
    • It offers a more objective and reliable method for visual field assessment in ophthalmology.
    • The system provides a hard copy of both pupil responses and subjective ratings, aiding in the verification of patient cooperation.