Related Experiment Video
Updated: Apr 5, 2026

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Optical Coherence Tomography Guided Percutaneous Coronary Intervention With Nobori Stent Implantation in Patients
Lisbeth Antonsen1, Per Thayssen2, Akiko Maehara2
1From the Department of Cardiology, Odense University Hospital, Odense, Denmark (L.A., P.T., H.S.H., A.J., K.T.V., K.N.H., M.H., L.O.J.); and Departments of Cardiology, Columbia University Medical Center and Cardiovascular Research Foundation, New York, NY (A.M., G.S.M.). Lisbeth.antonsen@rsyd.dk.
Background:
Incomplete strut coverage has been documented an important histopathologic morphometric predictor for later thrombotic events. This study sought to investigate whether optical coherence tomography (OCT)-guided percutaneous coronary intervention with Nobori biolimus-eluting stent implantation in patients with non-ST-segment-elevation myocardial infarction would provide improved strut coverage at 6 months in comparison with angiographic guidance only.
Methods And Results:
One hundred patients were randomized 1:1 to either OCT-guided or angio-guided Nobori biolimus-eluting stent implantation. Postprocedure OCT was performed in all patients. In the OCT-guided group, prespecified criteria indicating additional intervention were related to (1) stent underexpansion, (2) strut malapposition, (3) edge dissection(s), and (4) residual stenosis at the distal or proximal reference segment(s). A final OCT was performed in case of reintervention. Six-month OCT follow-up was available in 85 patients. Twenty-three (46%) OCT-guided patients had additional postdilation or stenting. The percentage of acutely malapposed struts was substantially lower in the OCT-guided group (3.4% [interquartile range, 0.3-7.6] versus 7.8% [interquartile range, 2.3-19.4]; P<0.01). At 6-month follow-up, the OCT-guided group had a significantly lower proportion of uncovered struts; 4.3% [interquartile range, 1.2-9.8] versus 9.0% [interquartile range, 5.5-14.5], P<0.01. Furthermore, OCT-guided patients had significantly more completely covered stents: 17.5% versus 2.2%, P=0.02. The percentages of malapposed struts and struts being both uncovered and malapposed at follow-up were comparable between groups.
Conclusions:
OCT-guided optimization of Nobori biolimus-eluting stent implantation improves strut coverage at 6-month follow-up in comparison with angiographic guidance alone.
Clinical Trial Registration:
URL: http://www.clinicaltrials.gov. Unique identifier: NCT02272283.