Related Experiment Video
Updated: Apr 5, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Transcatheter Left Atrial Appendage Closure Using Intracardiac Echocardiographic Guidance From the Left Atrium
Jean-Bernard Masson1, Rémi Kouz2, Mounir Riahi2
1Division of Cardiology, Centre Hospitalier Universitaire de Montréal, Montréal, Québec, Canada; Centre de recherche du Centre Hospitalier de l'Université de Montréal, Montréal, Québec, Canada.
Background:
Most commonly, left atrial appendage (LAA) occlusion procedures are performed using transesophageal echocardiography (TEE) guidance and general anaesthesia. Intracardiac echocardiography (ICE) offers potential advantages over TEE, however, ICE-guided LAA occlusion experience is limited and has been typically performed from a right-sided location where LAA visualization might be suboptimal. We sought to evaluate the efficacy and safety of percutaneous LAA occlusion using ICE guidance performed from the left atrium.
Methods:
Thirty-seven patients with atrial fibrillation, significant risk for stroke, and long-term contraindication to anticoagulation underwent LAA closure with the Amplatzer Cardiac Plug (St Jude Medical, Inc, St Paul, MN) with mild sedation and ICE guidance. The ICE catheter was introduced in the left atrium through a second transseptal puncture. Patients underwent preprocedural TEE to rule out thrombus and 3-month follow-up TEE to assess occlusion grade. Patient characteristics, procedural data, effectiveness of ICE imaging, quality of occlusion, and complications were prospectively recorded.
Results:
Procedural success was achieved in 36 of 37 patients (97%). Closure was complete or near complete (grade ≥3 according to ICE and angiography) in all cases where the device was released. In all cases, ICE imaging yielded good LAA and surrounding structure visualization and adequate procedural guidance. Three major procedural or in-hospital complications occurred. Median length of stay was 1 day. Follow-up TEE documented the absence of any residual peri-device leak in all but 1 (29 of 30) case.
Conclusion:
Initial experience suggests LAA occlusion with the Amplatzer Cardiac Plug using ICE guidance from the left atrium is feasible, reproducible, and safe.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization