Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

X-ray Crystallography02:18

X-ray Crystallography

26.9K
The size of the unit cell and the arrangement of atoms in a crystal may be determined from measurements of the diffraction of X-rays by the crystal, termed X-ray crystallography.
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
26.9K
Determination of Crystal Structures01:29

Determination of Crystal Structures

111
In the late 1800s, the revelation that light extended beyond visible wavelengths led to the discovery of X-rays by Wilhelm Roentgen. Recognized as high-energy electromagnetic radiation with short wavelengths, X-rays prompted exploration into their interaction with crystals. Max von Laue proposed in 1912 that the periodic arrangement of atoms, ions, or molecules in crystals would cause them to diffract X-rays, a hypothesis confirmed through experiments with copper sulfate and zinc sulfide...
111

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Gateway analysis reveals transient molecular programs at cell-fate transitions.

bioRxiv : the preprint server for biology·2026
Same author

Efficient computation of computer-generated dynamic holograms via phase-induced compressive-sensing Gerchberg-Saxton algorithm.

Optics express·2025
Same author

Highly Efficient Calibration-Free Color Compensation Algorithm for Imaging Flow Cytometry.

Cytometry. Part A : the journal of the International Society for Analytical Cytology·2025
Same author

Two-photon absorption in silicon using the real density matrix approach.

The Journal of chemical physics·2024
Same author

Mosaic-PICASSO: accurate crosstalk removal for multiplex fluorescence imaging.

Bioinformatics (Oxford, England)·2024
Same author

Optical trapping of sub-millimeter sized particles and microorganisms.

Scientific reports·2023
Same journal

Large-scale discovery and annotation of substructure patterns in mass spectrometry profiles.

Nature communications·2026
Same journal

Salmonella SopB suppresses post-transcriptionally regulated cytokine release to reduce early tissue inflammation and delay disease progression.

Nature communications·2026
Same journal

A human-specific microRNA controls the timing of excitatory synaptogenesis.

Nature communications·2026
Same journal

An HMA-like integrated domain in the wheat tandem kinase WTK4 recognises an RNase-like pathogen effector.

Nature communications·2026
Same journal

Learning regularities in noise engages both neural predictive activity and representational changes.

Nature communications·2026
Same journal

The H3K4 methyltransferase KMT2D is an essential cofactor for GATA1 at erythroid gene enhancers.

Nature communications·2026
See all related articles

Related Experiment Video

Updated: Apr 5, 2026

Synthesis and Microdiffraction at Extreme Pressures and Temperatures
07:26

Synthesis and Microdiffraction at Extreme Pressures and Temperatures

Published on: October 7, 2013

11.8K

Adiabatic far-field sub-diffraction imaging.

Hu Cang1, Alessandro Salandrino2, Yuan Wang2

  • 11] NSF Nanoscale Science and Engineering Center (NSEC), 3112 Etcheverry Hall, University of California, Berkeley, California 94720, USA [2] Waitt Advanced Biophotonics Center, Salk Institute for Bological Studies, 10010 North Torrey Pines Road, San Diego, California 92037, USA.

Nature Communications
|August 11, 2015
PubMed
Summary
This summary is machine-generated.

Researchers developed an adiabatic lens to overcome optical imaging resolution limits. This new method enables far-field imaging of near-field features, achieving sub-50 nm resolution in visible light.

More Related Videos

Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene
08:44

Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene

Published on: August 22, 2017

8.2K
Femtosecond Laser Filaments for Use in Sub-Diffraction-Limited Imaging and Remote Sensing
06:16

Femtosecond Laser Filaments for Use in Sub-Diffraction-Limited Imaging and Remote Sensing

Published on: April 25, 2019

8.1K

Related Experiment Videos

Last Updated: Apr 5, 2026

Synthesis and Microdiffraction at Extreme Pressures and Temperatures
07:26

Synthesis and Microdiffraction at Extreme Pressures and Temperatures

Published on: October 7, 2013

11.8K
Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene
08:44

Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene

Published on: August 22, 2017

8.2K
Femtosecond Laser Filaments for Use in Sub-Diffraction-Limited Imaging and Remote Sensing
06:16

Femtosecond Laser Filaments for Use in Sub-Diffraction-Limited Imaging and Remote Sensing

Published on: April 25, 2019

8.1K

Area of Science:

  • Optics and Photonics
  • Nanotechnology
  • Materials Science

Background:

  • Conventional optical imaging is limited by evanescent waves carrying fine feature information.
  • Evanescent waves decay exponentially, preventing them from reaching the imaging plane in traditional systems.

Purpose of the Study:

  • To introduce a novel adiabatic lens for overcoming the resolution limitations of conventional optical imaging.
  • To enable far-field optical systems to image near-field features directly.

Main Methods:

  • Utilizing a geometrically conformal surface to mediate the interference of slowly decompressed electromagnetic waves.
  • Employing an adiabatic condition for wave decompression to bridge the near-field and far-field gap.

Main Results:

  • Demonstrated magnification of up to 20 times.
  • Achieved sub-50 nanometer imaging resolution in the visible spectrum.
  • Successfully projected near-field features into the far-field for imaging.

Conclusions:

  • The adiabatic lens extends the capabilities of geometrical optics to the deep sub-wavelength scale.
  • This approach offers a new pathway for high-resolution optical imaging beyond conventional limits.