An Advanced Bolus Calculator for Type 1 Diabetes: System Architecture and Usability Results
Abstract:
This paper presents the architecture and initial usability results of an advanced insulin bolus calculator for diabetes (ABC4D), which provides personalized insulin recommendations for people with diabetes by differentiating between various diabetes scenarios and automatically adjusting its parameters over time. The proposed platform comprises two main components: a smartphone-based patient platform allowing manual input of glucose and variables affecting blood glucose levels (e.g., meal carbohydrate content and exercise) and providing real-time insulin bolus recommendations; and a clinical revision platform to supervise the automatic adaptations of the bolus calculator parameters. The system implements a previously in silico validated bolus calculator algorithm based on case-based reasoning, which uses information from similar past events (i.e., cases) to suggest improved personalized insulin bolus recommendations and automatically learns from new events. Usability of ABC4D was assessed by analyzing the system usage at the end of a six-week pilot study (n = 10). Further feedback on the use of ABC4D has been obtained from each participant at the end of the study from a usability questionnaire. On average, each participant requested 115 ± 21 insulin recommendations, of which 103 ± 28 (90%) were accepted. The clinical revision software proposed a total of 754 case revisions, where 723 (96%) adaptations were approved by a clinical expert and updated in the patient platform.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...