Related Experiment Video
Updated: Apr 5, 2026

A Tuberculosis Molecular Bacterial Load Assay TB-MBLA
Published on: April 30, 2020
Auditing smear microscopy results according to time to detection using the BACTEC™ MGIT™ TB system
1Royal Free London NHS Foundation Trust, Department of Medical Microbiology, Barnet Hospital, Wellhouse Lane, Barnet, UK.
Abstract:
Smear microscopy is a rapid method for the identification of the most infectious patients with mycobacterial infection. Suboptimal smear microscopy may significantly compromise or delay patient isolation and contact tracing. A stringent method for auditing mycobacterial smear results is thus needed. This article proposes an auditing tool based on time to detection (TTD) of culture-positive samples using the automated BACTEC™ MGIT™ 960 TB system. In our study, sputum samples subjected to liquefaction and concentration before staining with a TTD of ≤ 13 days using the BACTEC system should be positive on smear microscopy.
More Related Videos
06:26Author Spotlight: Optimizing CFU Determination for Efficient Assessment of TB Vaccine Efficacy and Antigen Presentation Analysis
Published on: July 28, 2023
12:39Antimicrobial Susceptibility Testing of Mycobacterium Tuberculosis Complex for First and Second Line Drugs by Broth Dilution in a Microtiter Plate Format
Published on: June 24, 2011