Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
Published on: May 23, 2013
3D motion reliability of occipital condylar glide testing: From concept to kinematics evidence
Benoît Beyer1, Stéphane Sobczak2, Walid Salem3
1Research Unit in Osteopathy, Faculty of Motor Sciences, Université Libre de Bruxelles (ULB), Brussels, Belgium; Laboratory of Functional Anatomy, Faculty of Motor Sciences, Université Libre de Bruxelles (ULB), Brussels, Belgium; Laboratory of Anatomy, Biomechanics and Organogenesis (LABO), Faculty of Medicine, Université Libre de Bruxelles (ULB), Brussels, Belgium.
Background:
To date, segmental data analyzing kinematics of occipital condylar testing or mobilization is lacking.
Objectives:
The objective of this study was to assess occipitoatlantal 3D motion components and to analyze inter- and intra-rater reliability during in vitro condylar glide test.
Methods:
To conduct this study, four fresh cadavers were included. Dissection was carried out to ensure technical clusters placement to skull, C1 and C2. During condylar glide test, bone motion data was computed using an optoelectronic system. The reliability of motion kinematics was assessed for three skilled practitioners performing two sessions of 3 trials on two days interval.
Findings:
During testing, average absolute motion ROM (±SD) were up to 4.1 ± 2.1°, 0.7 ± 1.3° and 10.3 ± 2.5° for occipitoatlantal lateral bending, axial rotation and flexion-extension, respectively. For position variation, magnitudes were 2.3 ± 1.8 mm, 1.1 ± 1.3 mm and 2.6 ± 0.8 mm for anteroposterior, cephalocaudal and mediolateral displacements. Concerning motion reliability, variation ranged from 0.6° to 3.4° and from 0.3 mm to 1.6 mm for angular displacement and condyle position variation, respectively. In general, good to excellent agreement was observed (ICC ranging from 0.728 to 0.978) for the same operator, while consistency was limited to lateral/side bending and lateral condyle displacement between operators, with respective ICCs of 0.800 and 0.955.
Conclusions:
This study shows specific motion patterns involving extension and lateral bending of the occipitoatlantal level for anterior condylar glide test. In addition, condyle position variation demonstrated coupled components in forward and heterolateral directions. However, task seems not to be side specific. In general, reliability of 3D motion components showed good intra-operator agreement and limited inter-operator agreement.
Related Concept Videos
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Mechanism of Ciliary Motion
The cilia are made up of microtubules in a 9+2 arrangement, with nine microtubule doublet ring bundles, surrounding a pair of central singlet microtubule bundles. The doublet microtubule bundles are...
Mechanism of Ciliary Motion
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...