On the Fine Isotopic Distribution and Limits to Resolution in Mass Spectrometry

Piotr Dittwald1,2, Dirk Valkenborg3,4,5, Jürgen Claesen5

  • 1Institute of Informatics, University of Warsaw, Warsaw, Poland.

Related Concept Videos

High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.9K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
2.1K
Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
5.0K
Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
4.3K
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
3.0K
MALDI-TOF Mass Spectrometry01:19

MALDI-TOF Mass Spectrometry

Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
7.6K