Related Experiment Video
Updated: Apr 5, 2026

Genetic Analysis of Hereditary Transthyretin Ala97Ser Related Amyloidosis
Published on: June 9, 2018
How Can We Improve the Detection of Alpha1-Antitrypsin Deficiency?
Ilaria Ferrarotti1, Beata Poplawska-Wisniewska2, Maria Teresa Trevisan3
1Department of Molecular Medicine, Pneumology Unit, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy.
Abstract:
The Z deficiency in α1-antitrypsin (A1ATD) is an under-recognized condition. Alpha1-antitrypsin (A1AT) is the main protein in the α1-globulin fraction of serum protein electrophoresis (SPE); however, evaluation of the α1-globulin protein fraction has received very little attention. Serum Z-type A1AT manifests in polymeric forms, but their interference with quantitative immunoassays has not been reported. Here, 214 894 samples were evaluated by SPE at the G. Fracastoro Hospital of Verona, Italy. Patients with an A1AT level ≤ 0.92 g/L were recalled to complete A1ATD diagnosis. In parallel, to qualitatively and quantitatively characterize A1AT, sera samples from 10 PiZZ and 10 PiMM subjects obtained at the National Institute of Tuberculosis and Lung Diseases in Warsaw, Poland, were subjected to non-denaturing 7.5% PAGE and 7.5% SDS-PAGE followed by Western blot. Moreover, purified A1AT was heated at 60°C and analyzed by a non-denaturing PAGE and 4-15% gradient SDS-PAGE followed by Western blot as well as by isolelectrofocusing and nephelometry. A total of 966 samples manifested percentages ≤ 2.8 or a double band in the alpha1-zone. According to the nephelometry data, 23 samples were classified as severe (A1AT ≤ 0.49 g/L) and 462 as intermediate (A1AT >0.49≤ 1.0 g/L) A1ATD. Twenty subjects agreed to complete the diagnosis and an additional 21 subjects agreed to family screening. We detected 9 cases with severe and 26 with intermediate A1ATD. Parallel experiments revealed that polymerization of M-type A1AT, when measured by nephelometry or isolelectrofocusing, yields inaccurate results, leading to the erroneous impression that it was Z type and not M-type A1AT. We illustrate the need for confirmation of Z A1AT values by "state of the art" method. Clinicians should consider a more in-depth investigation of A1ATD in patients when they exhibit serum polymers and low α1-globulin protein levels by SPE.
More Related Videos
12:01Detection of Disease-associated α-synuclein by Enhanced ELISA in the Brain of Transgenic Mice Overexpressing Human A53T Mutated α-synuclein
Published on: May 30, 2015
11:03Use of Capillary Electrophoresis Immunoassay to Search for Potential Biomarkers of Amyotrophic Lateral Sclerosis in Human Platelets
Published on: February 10, 2020
Related Concept Videos
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Pneumonia III: Complications and Assessment