Related Experiment Video
Updated: Jul 21, 2026

Preparation of Rat Tail Tendons for Biomechanical and Mechanobiological Studies
Published on: July 30, 2010
Converting round tendons to flat tendon constructs: Does the preparation process have an influence on the structural
C Domnick1, M Herbort2, M J Raschke1
1Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University Muenster, Waldeyer Strasse 1, 48149, Muenster, Germany.
Purpose:
The structural properties of hamstring tendon grafts were evaluated in a porcine model, after processing it to a flat shape, to better replace or augment anatomic flat structures (e.g. ACL, MPFL or MCL).
Methods:
In this biomechanical study, porcine flexor tendons were used which have a comparable shape to semitendinosus and gracilis tendons. One part of the tendon was prepared to a flat tendon construct by splitting the tendon longitudinally with a knife to half of the diameter of the tendon. The semi-split tendon was scratched out to a flat shape. The other matched part was tested in its original round shape. The tendons (n = 40) have been fixed in a uniaxial testing machine (Zwick/Roell) by cryo-clamps after preparing the fixed ends by 2-0 polyester sutures (2-0 Ethibond® EXCEL, Ethicon, Somerville, NJ). In every specimen, there was a free 60-mm tendon part between both clamps. The tendons have been loaded to failure to evaluate typical biomechanical parameters such as stiffness, yield load and maximum load.
Results:
No statistically significant differences (n.s.) regarding stiffness, yield load and maximum load between natively round and processed flat tendons could be detected.
Conclusion:
A prepared flat-shaped tendon does not show any different structural properties compared with an original round tendon. Therefore, a flat tendon seems to be a biomechanical stable graft option for anatomic reconstruction or augmentation of injured natively flat-shaped structures such as MCL, MPFL or ACL.