Related Experiment Video
Updated: Apr 5, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Stridor in Neonates After Using the Microcuff® and Uncuffed Tracheal Tubes: A Retrospective Review
Madhankumar Sathyamoorthy1, Jerrold Lerman, Rajeshri Asariparampil
1From the *Department of Anesthesiology, Women and Children's Hospital of Buffalo, Buffalo, New York, and SUNY at Buffalo, Buffalo, New York; †Department of Anesthesiology, University of Rochester, Rochester, New York; ‡Department of Medicine and Biostatistics, University of Mississippi Medical Center, Jackson, Mississippi; and §Department of Pediatrics, SUNY at Buffalo, Buffalo, New York.
Background:
We conducted a retrospective chart review to determine the frequency of stridor and contributing factors after the use of Microcuff® and uncuffed tracheal tubes (TTs) in neonates.
Methods:
All neonates in our neonatal intensive care unit whose airways were intubated between May 2011 and June 2012 were included. Data were collected from the neonatal intensive care unit database and from the electronic anesthesia record. Extracted data included postmenstrual age (PMA) at birth, birth weight, TT size and type, duration of tracheal intubation, and number of reintubations. The use of racemic epinephrine, heliox, and/or dexamethasone postextubation was considered diagnostic of stridor.
Results:
Of the 324 neonates whose data were reviewed, 27 (8.3%) developed postextubation stridor. Neonates who developed stridor were more premature (PMA at birth, 29.9 ± 5.8 vs 33.0 ± 4.8 weeks, P = 0.001), had a lower birth weight (1.56 ± 1.07 vs 2.02 ± 0.96 kg, P = 0.005), greater duration of intubation (median: 20 vs 3 days, P < 0.0001), and multiple reintubations (median: 2 vs 0, P < 0.0001). The frequency of stridor was 17.2% after using Microcuff TT and 7.5% after using uncuffed TTs (Fisher exact test, 2-sided P = 0.08 [95% confidence interval for difference in proportions: -9.4% to 28.7%]). In a multivariable logistic regression model, after adjusting for PMA, birth weight, duration of intubation, and number of reintubations, the use of a Microcuff TT was associated with increased odds of stridor (adjusted odds ratio = 9.27 [95% confidence interval: 1.88-45.67], P = 0.006).
Conclusions:
The use of the Microcuff TT is associated with increased odds of postextubation stridor in neonates compared with the use of uncuffed TT.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...

