Screening Tests for Cushing's Syndrome: Urinary Free Cortisol Role Measured by LC-MS/MS
Filippo Ceccato1, Mattia Barbot1, Marialuisa Zilio1
1Endocrinology Unit (F.C., M.Ba., M.Z., N.A., V.C., F.M., M.Bo., C.S.) and Laboratory Medicine Unit (G.A., M.P.), Department of Medicine, and Unit of Biostatistics, Epidemiology, and Public Health (A.C.F.), Department of Cardiac, Thoracic, and Vascular Sciences, University-Hospital of Padova, 35128 Padova, Italy.
Introduction And Aim:
As initial screening for Cushing's syndrome (CS), The Endocrine Society guidelines recommend one of the following: the 1-mg dexamethasone suppression test (DST) or late-night salivary cortisol (LNSC) or urinary free cortisol (UFC) measurement. We examined the diagnostic performance of the above-mentioned tests in a series of patients.
Materials And Methods:
We retrospectively analyzed 137 patients with clinical conditions suggestive of hypercortisolism: 38 with confirmed CS diagnosis and 99 without (termed non-CS). UFC was measured by liquid chromatography tandem-mass spectrometry, whereas LNSC by the radioimmunometric method and serum cortisol were measured by a chemiluminescence immunoassay.
Results:
Comparing CS vs non-CS, a cutoff of 138 nmol/L after 1-mg DST revealed the best specificity (SP; 97%), whereas the 50-nmol/L cutoff confirmed the best sensitivity (SE; 100%); the SE and SP for LNSC greater than 14.46 nmol/L were, respectively, 84% and 89%, whereas the SE and SP for UFC greater than 170 nmol per 24 hours, they were 97% and 91%. Overall, UFC revealed both a combined higher positive and a lower negative likelihood ratio among first-line tests (respectively 10.7 and 0.03). Computing a receiver-operating curve -contrast analysis to compare the power of each single test with that of the others, alone or combined (DST+LNSC, DST+UFC, and LNSC+UFC) or with that of all the tests together (DST+LNSC+UFC), the UFC assay was at least as good as all the other possible combinations.
Conclusions:
Measuring UFC by liquid chromatography tandem-mass spectrometry achieves the best accuracy in diagnosing CS among patients presenting with suspected hypercortisolism.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Related Concept Videos
Cushing Syndrome I: Introduction
Cushing Syndrome II: Pathophysiology