Bastian Kern1, Dmitry Strelnikov1, Patrick Weis1
1Institute of Physical Chemistry II, KIT, Fritz-Haber-Weg 2, 76131 Karlsruhe, Germany.
Abstract:
C60(2+) and C60(3+) were produced by electron-impact ionization of sublimed C60 and charge-state-selectively codeposited onto a gold mirror substrate held at 5 K together with neon matrix gas containing a few percent of the electron scavengers CO2 or CCl4. This procedure limits charge-changing of the incident fullerene projectiles during matrix isolation. IR, NIR, and UV-vis spectra were then measured. Ten IR absorptions of C60(2+) were identified. C60(3+) was observed to absorb in the NIR region close to the known vibronic bands of C60(+). UV spectra of C60, C60(+), and C60(2+) were almost indistinguishable, consistent with a plasmon-like nature of their UV absorptions. The measurements were supported by DFT and TDDFT calculations, revealing that C60(2+) has a singlet D5d ground state whereas C60(3+) forms a doublet of Ci symmetry. The new results may be of interest regarding the presence of C60(2+) and C60(3+) in space.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
09:41Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
Published on: June 9, 2016
Related Concept Videos
Spectroscopy of Carboxylic Acid Derivatives
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Molecular Spectroscopy: Absorption and Emission
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...