Related Experiment Video
Updated: Apr 5, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion Artifacts
Goal:
Although photoplethysmographic (PPG) signals can monitor heart rate (HR) quite conveniently in hospital environments, trying to incorporate them during fitness programs poses a great challenge, since in these cases, the signals are heavily corrupted by motion artifacts.
Methods:
In this paper, we present a novel signal processing framework which utilizes two channel PPG signals and estimates HR in two stages. The first stage eliminates any chances of a runaway error by resorting to an absolute criterion condition based on ensemble empirical mode decomposition. This stage enables the algorithm to depend very little on the previously estimated HR values and to discard the need of an initial resting phase. The second stage, on the other hand, increases the algorithm's robustness against offtrack errors by using recursive least squares filters complemented with an additional novel technique, namely time-domain extraction.
Results:
Using this framework, an average absolute error of 1.02 beat per minute (BPM) and standard deviation of 1.79 BPM are recorded for 12 subjects performing a run with peak velocities reaching as high as 15 km/h.
Conclusion:
The performance of this algorithm is found to be better than the other recently reported algorithms in this field such as TROIKA and JOSS.
Significance:
This method is expected to greatly facilitate the presently available wearable gadgets in HR computation during various physical activities.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Holter Monitor: 24-Hour Monitoring
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...

