Related Experiment Video
Updated: Apr 5, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea
José Antonio Pinto1, Luciana Balester Mello de Godoy1, Renata Coutinho Ribeiro2
1Department of Otorhinolaryngology, Hospital São Camilo, Pompéia, São Paulo, SP, Brazil; Otorhinolaryngology and Head and Neck Surgery and Sleep Medicine Center of São Paulo (NOSP), São Paulo, SP, Brazil.
Introduction:
The use of handheld devices that assess peripheral arterial tonometry has emerged as an auxiliary method for assessment and diagnosis of obstructive sleep apnea syndrome.
Objective:
To evaluate the accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea.
Methods:
Contemporary cohort cross-sectional study. Thirty patients with suspected obstructive sleep apnea underwent peripheral arterial tonometry and assisted nocturnal polysomnography concomitantly.
Results:
The mean apnea/hypopnea index by peripheral arterial tonometry was significantly higher than that by polysomnography (p<0.001), but the values of both sleep studies were significantly correlated (r=0.762). There was a high correlation between variables: minimum oxygen saturation (r=0.842, p<0.001), oxygen saturation<90% (r=0.799, p<0.001), and mean heart rate (r=0.951, p<0.001). Sensitivity and specificity were 60% and 96.2% (AUC: 0.727; p=0.113), respectively, when at a threshold value of 5 events/h. In severe cases (≥30 events/h), the result was a sensitivity of 77.8% and a specificity of 86.4% (AUC: 0.846, p=0.003).
Conclusion:
Peripheral arterial tonometry is a useful portable device for the diagnosis of obstructive sleep apnea; its accuracy is higher in moderate and severe cases.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure