Related Experiment Video
Updated: Apr 5, 2026

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
Published on: August 16, 2019
Caprylic acid-induced impurity precipitation from protein A capture column elution pool to enable a
Ji Zheng1, Lu Wang1, Barbara Twarowska1
1Biologics Development Dept., Bristol-Myers Squibb, Bloomsbury, NJ, 08804.
Abstract:
This article presents the use of caprylic acid (CA) to precipitate impurities from the protein A capture column elution pool for the purification of monoclonal antibodies (mAbs) with the objective of developing a two chromatography step antibody purification process. A CA-induced impurity precipitation in the protein A column elution pool was evaluated as an alternative method to polishing chromatography techniques for use in the purification of mAbs. Parameters including pH, CA concentrations, mixing time, mAb concentrations, buffer systems, and incubation temperatures were evaluated on their impacts on the impurity removal, high-molecular weight (HMW) formation and precipitation step yield. Both pH and CA concentration, but not mAb concentrations and buffer systems, are key parameters that can affect host-cell proteins (HCPs) clearance, HMW species, and yield. CA precipitation removes HCPs and some HMW species to the acceptable levels under the optimal conditions. The CA precipitation process is robust at 15-25°C. For all five mAbs tested in this study, the optimal CA concentration range is 0.5-1.0%, while the pH range is from 5.0 to 6.0. A purification process using two chromatography steps (protein A capture column and ion exchange polishing column) in combination with CA-based impurity precipitation step can be used as a robust downstream process for mAb molecules with a broad range of isoelectric points. Residual CA can be effectively removed by the subsequent polishing cation exchange chromatography.
More Related Videos
10:08An Economical and Versatile High-Throughput Protein Purification System Using a Multi-Column Plate Adapter
Published on: May 21, 2021
10:33Isolation and Characterization Of Chimeric Human Fc-expressing Proteins Using Protein A Membrane Adsorbers And A Streamlined Workflow
Published on: January 8, 2014
Related Concept Videos
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Affinity Chromatography