A cervical "zero-profile" cage with integrated angle-stable fixation: 24-months results
Acta Orthopaedica Belgica
|August 18, 2015
Summary
This study shows a new zero-profile stand-alone cage is safe and effective for anterior cervical fusion, achieving a 97% fusion rate with minimal complications like dysphagia.
Area of Science:
- Spinal Surgery
- Orthopedic Implants
- Cervical Spine Fusion
Background:
- Anterior cervical fusion is a common procedure for cervical spine pathologies.
- Existing implants may have limitations in terms of profile and fixation.
- Novel devices aim to improve safety, efficacy, and patient outcomes.
Purpose of the Study:
- To evaluate the mid-term safety and efficacy of a novel "zero-profile" stand-alone cage.
- To assess fusion rates, implant stability, and complication incidence.
- To determine the device's suitability for single- and multilevel anterior cervical fusions.
Main Methods:
- Prospective, mono-centric case series.
- 53 patients underwent anterior cervical discectomy and fusion with the "zero-profile" implant.
- Minimum 24-month follow-up, including CT scans at 12 months for fusion assessment.
Main Results:
- Achieved an overall fusion rate of 97%.
- No instances of hardware failure were recorded.
- A low rate of mild dysphagia (6.6%) was observed at 24 months.
Conclusions:
- The "zero-profile" stand-alone cervical cage demonstrates safety and efficacy.
- It facilitates effective anterior cervical decompression and stabilization.
- Further randomized trials are recommended to validate these findings.
Related Concept Videos
Articulations of the Vertebral Column
3.7K
In addition to being held together by the intervertebral discs, adjacent vertebrae also articulate with each other at synovial joints formed between the superior and inferior articular processes called zygapophysial joints (facet joints). These are plane joints that provide for only limited motions between the vertebrae. The orientation of the articular processes at these joints varies in different regions of the vertebral column and serves to determine the types of motions available in each...
3.7K
Unsymmetric Bending - Angle of Neutral Axis
1.0K
Unsymmetrical bending occurs when a structural member is subjected to bending moments in a plane that does not align with the member's principal axes. This scenario typically arises in beams and other structural components when loads are applied at non-ideal angles, introducing complexities in stress analysis.
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal...
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal...
1.0K