Related Experiment Video
Updated: Apr 5, 2026

A Novel Application of Musculoskeletal Ultrasound Imaging
Published on: September 17, 2013
Sonographical parameters of the finger pulley system in healthy adults
Dominik Bassemir1, Frank Unglaub1,2, Peter Hahn1
1Department of Hand Surgery, Vulpius Klinik, Vulpiusstraße 29, 74906, Bad Rappenau, Germany.
Introduction:
To establish normative values of tendon to bone distances (TBDs) to evaluate the A2 and A4 annular pulley integrity, we hypothesized that these values correlate with gender, athletic exercise, occupation, individual's age and body height.
Methods:
Ultrasonography of 200 healthy individuals was performed prospectively. TBDs for the A2 and A4 pulley sections were measured for all fingers. Evaluation was performed in resting position and active forced flexion. Examination parameters included gender, age, body height, occupation, athletic exercise level, and hand dominance. Assessment of resting position and active forced flexion was done.
Results:
No clinically relevant differences of TBDs with respect to the aforementioned parameters were observed. But TBDs were significantly greater in active forced flexion than in resting position for all measured pulley sections. Intraobserver reliability was very satisfactory.
Conclusions:
Establishing normative values will help to detect injured pulleys more precisely and examination should be performed both in resting position and active forced flexion.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pulse
The pulse serves as a clinical...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.