Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Clinical evaluation of semiautomatic and automatic devices for home blood pressure measurement: comparison between
1Department of Medicine, Tohoku University School of Medicine, Sendai, Japan.
Abstract:
The accuracy and reliability of blood pressure (BP) values were evaluated by comparing values obtained with eight automatic or semiautomatic devices designed for home BP measurement (four microphone devices based on the Korotkoff-sound technique and four cuff-oscillometric devices) with those obtained by the auscultatory method, using a standard mercury sphygmomanometer. Systolic blood pressure (SBP) values obtained using the microphone devices coincided well with those obtained by the auscultatory method. However, these devices produced a certain proportion of errors in the measurement of diastolic blood pressure (DBP), sometimes resulting in recordings at least 25 mmHg higher than those obtained by the standard method. The most frequent causes of this phenomenon were an auscultatory (silent) gap and a weak Korotkoff sound after phase IV. A microphone device using a condenser microphone built into the manometer displayed comparatively good acoustic characteristics for determining DBP. All cuff-oscillometric devices demonstrated minimal mean differences and a constant s.d. of mean difference for DBP, with no great differences from the auscultatory method. However, mean differences and s.d.s in SBP measurements using cuff-oscillometric devices were relatively greater than those obtained using some of the microphone devices. Furthermore, the direction of the mean differences in measurements from those obtained with the auscultatory method differed. The error in relation to the auscultatory method tended to be reproducible in the same subjects with both the microphone and the cuff-oscillometric devices.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure