Related Experiment Video
Updated: Apr 5, 2026

Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
Late Rupture of Abdominal Aortic Aneurysm After Previous Endovascular Repair: A Systematic Review and Meta-analysis
George A Antoniou1, George S Georgiadis2, Stavros A Antoniou3
1Liverpool Vascular and Endovascular Service, Royal Liverpool University Hospital, Liverpool, UK antoniou.ga@hotmail.com.
Purpose:
To report a systematic literature review of late rupture of abdominal aortic aneurysm (AAA) after endovascular aneurysm repair (EVAR) and the results of a pooled analysis of causes, treatment, and outcomes.
Methods:
Electronic information sources and bibliographic reference lists were interrogated using a combination of free text and controlled vocabulary searches; 11 articles were ultimately identified that fulfilled the inclusion criteria. The articles reported a total of 190 patients who were included in the qualitative and quantitative synthesis. Mortality within 30 days or during the admission with aneurysm rupture was a primary endpoint; major perioperative morbidity was a secondary endpoint. A meta-analysis was performed for 30-day/in-hospital mortality using the random effects model.
Results:
A total of 152 ruptures occurred after 16,974 EVAR procedures reported by 8 of the case series, giving an incidence of 0.9% [95% confidence interval (CI) 0.77 to 1.05]. The mean time to rupture was 37 months. Twenty-nine percent (95% CI 20 to 39) of the patients had at least one previous secondary endovascular intervention following the initial EVAR, and 37% (95% CI 30 to 45) were not compliant with surveillance. Type I and III endoleaks were the predominant causes of rupture. Open surgical treatment was undertaken in 61% (95% CI 53 to 68) of the patients who underwent treatment. The pooled estimate for perioperative mortality was 32% (95% CI 24 to 41). A significantly lower mortality was found with endovascular treatment than open surgical management (p=0.027).
Conclusion:
Graft-related endoleaks appear to be the predominant causes of late aneurysm rupture. Quality of and compliance with post-EVAR surveillance are important factors in late rupture; a large proportion of late ruptures are amenable to endovascular treatment.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm I: Introduction