Blood pressure monitoring during exercise: comparison of pulse transit time and volume clamp methods
Thomas Wibmer1, Coy Denner1, Christoph Fischer2,3
1a Department of Internal Medicine II , University Hospital of Ulm , Ulm , Germany.
Abstract:
During physical exercise, pulse transit time (PTT), expressed as the interval between ventricular electrical activity and peripheral pulse wave, may provide a surrogate estimate for blood pressure by the use of specific calibration procedures. The objective of this study was to determine systolic blood pressure (SBP) values derived from the PTT method and from an established method of non-invasive continuous blood pressure measurement based on the volume clamp technique, and to compare their agreement with sphygmomanometry during exercise tests. In 18 subjects, electrocardiogram (ECG) and finger-photoplethysmography were continuously recorded during maximal cycle exercise tests. Intermittent and continuous blood pressure measurements were simultaneously taken using automated sphygmomanometry and a Portapres Model-2 device, respectively. PTT was calculated for each ECG R-wave and the corresponding steepest upstroke slope in the photoplethysmogram, and was transformed to a continuous blood pressure estimate using multipoint nonlinear regression calibration based on the individual subject's sphygmomanometer readings. Bland-Altman limits of agreement between PTT-derived SBP estimates and sphygmomanometer values were -24.7 to 24.1 mmHg, and between Portapres and sphygmomanometer SBP values were -42.0 to 70.1 mmHg. For beat-to-beat SBP estimation during exercise, PTT measurement combined with multipoint nonlinear regression calibration based on intermittent sphygmomanometry may be an alternative to volume clamp devices.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: