Elucidating Operating Modes of Bulk-Heterojunction Solar Cells from Impedance Spectroscopy Analysis

Germà Garcia-Belmonte1, Antonio Guerrero1, Juan Bisquert1

  • 1Photovoltaic and Optoelectronic Devices Group, Departament de Física, Universitat Jaume I, ES-12071 Castelló, Spain.

Related Concept Videos

P-N junction01:11

P-N junction

A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
1.7K
Debye–Huckel–Onsager Conductance Equation01:28

Debye–Huckel–Onsager Conductance Equation

The Debye-Hückel-Onsager equation is a cornerstone of physical chemistry, providing a method to determine the molar conductance (Λm) and molar conductance at infinite dilution (Λ°m) for uni-univalent electrolytes.Uni-univalent electrolytes are electrolytes that dissociate in solution to produce one cation with a +1 charge and one anion with a –1 charge per formula unit.This equation addresses two crucial phenomena: the asymmetry effect and the electrophoretic effect.
215
Modes of Operations of BJT01:21

Modes of Operations of BJT

A Bipolar Junction Transistor (BJT) is a versatile component in electronics, functioning in four distinct modes based on the biasing of its junctions: active, saturation, cut-off, and inverted modes.
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...
2.3K
Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
1.2K