Background:
Many patients exposed to heparin develop antibodies against platelet factor 4 (PF4) and heparin, yet only those antibodies that activate platelets cause heparin-induced thrombocytopenia (HIT). Patients who produce anti-PF4/heparin antibodies without developing HIT either have antibodies that do not cause platelet activation or produce pathogenic antibodies at levels that are insufficient to cause HIT. Understanding the differences between anti-PF4/heparin antibodies with and without HIT will improve test methods and reduce overdiagnosis.
Aims:
To investigate the presence of low levels of platelet-activating antibodies in patients investigated for HIT who had anti-PF4/heparin antibodies but failed to cause platelet activation in the (14) C-serotonin release assay (SRA).
Materials/Methods:
We developed a platelet activation assay similar to the SRA using exogenous PF4 without added heparin (PF4-SRA). This assay was able to detect low levels of platelet-activating antibodies. We used this PF4-SRA to test for platelet-activating antibodies in patients investigated for HIT.
Results:
The PF4-SRA detected platelet-activating antibodies in seven (100%) of seven SRA-positive sera even after the samples were diluted until they were no longer positive in the standard SRA. Platelet-activating antibodies were detected in 14 (36%) of 39 patients who had anti-PF4/heparin antibodies but tested negative in the SRA and did not have clinical HIT. The clinical diagnosis of HIT was confirmed by chart review and concordant with the SRA results.
Conclusions:
A subset of heparin-treated patients produce subthreshold levels of platelet-activating anti-PF4/heparin antibodies that do not cause HIT. An increase in the titer of these pathogenic antibodies, along with permissive clinical conditions, could lead to HIT.
More Related Videos
04:32A Uniform Shear Assay for Human Platelet and Cell Surface Receptors via Cone-plate Viscometry
Published on: June 5, 2019
10:05Simultaneous Distinction of Monospecific and Mixed DFS70 Patterns During ANA Screening with a Novel HEp-2 ELITE/DFS70 Knockout Substrate
Published on: January 17, 2018
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target...