Related Experiment Video
Updated: Apr 5, 2026

Y-90 Radioembolization and PD-1 Inhibitor as Neoadjuvant Treatment in Hepatocellular Carcinoma
Published on: May 24, 2024
Imaging Predictors of Elevated Lung Shunt Fraction in Patients Being Considered for Yttrium-90 Radioembolization
Olufoladare G Olorunsola1, Maureen P Kohi1, Spencer C Behr1
1Department of Radiology, University of California, San Francisco, 505 Parnassus Avenue, Room 361, San Francisco, CA 94143.
Purpose:
To identify imaging findings associated with elevated lung shunt fraction (LSF) in patients being considered for yttrium-90 ((90)Y) radioembolization.
Materials And Methods:
During the period 2009-2014, 152 consecutive patients underwent planning hepatic arteriography with technetium-99m ((99m)Tc) macroaggregated albumin (MAA) injection. Computed tomography (CT) or magnetic resonance imaging performed before the procedure for each patient was assessed for hepatic vein (HV) tumor thrombus or occlusion from external compression by tumor. When imaging was a multiphase CT scan (117 patients), the arterial phase was evaluated for evidence of early HV opacification (relative to unaffected HVs), indicating hepatic venous shunting. These factors were correlated with LSF determined by (99m)Tc-MAA imaging.
Results:
Median LSF was 6.7% (range, < 0.1%-71%), significantly higher for HCC (8.0% vs 6.3% for other tumors, P = .048). Larger tumor size was associated with higher LSF in univariate analysis (P = .001). There was high interobserver agreement for determining hepatic venous shunting (97%, κ = 0.847), which was associated with higher LSF (P < .001; 78% sensitivity, 93% specificity). Of 5 cases of HV tumor thrombus, all had high (> 20%) LSF (P < .001). HV occlusion was also associated with higher LSF (P = .039). Multivariate analysis confirmed that early HV opacification and either HV tumor thrombus or occlusion were associated with higher LSF.
Conclusions:
Early HV opacification and HV tumor thrombus or occlusion on cross-sectional imaging performed before radioembolization are associated with elevated LSF, which may contraindicate or limit the dose delivered in (90)Y radioembolization. This information could be helpful during patient counseling for anticipating the most appropriate mode of liver-directed therapy.
More Related Videos
07:07Tumor Hypoxia Assessment: In Vivo 3D Oxygen Imaging Through Electron Paramagnetic Resonance
Published on: February 14, 2025
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET