[Dose management in radiology: Review of the technological status]
1Universitätsklinik für Radiologie, LKH Innsbruck, Anichstr. 35, 6020, Innsbruck, Österreich, michael.verius@i-med.ac.at.
Background:
The Euratom directive 2013/59 ("EU directive for radiation protection") has to be implemented into national law by spring 2018 and requires a complete recording of patient dosages and relevant parameters. Additionally, a medical physics expert has to be consulted for each radiological examination above a defined threshold.
Objectives:
A complete recording of the dosage administered from all modalities and optimization of the radiological procedures should result in a reduction of the total dosage.
Material And Methods:
This can be achieved by automated systems that incorporate not only the detection of the dose parameters but also the evaluation and analysis of these data. When provided with warning levels such a system should be able to inform or warn the operator when dose thresholds have been exceeded or even better inform the operator about possible excess dosages before an examination. Depending on the information provided by the modality, dose management systems can operate at different levels in the picture archiving and communication system (PACS), radiological and hospital information systems (RIS/HIS) or with the header information of a digital imaging and communications in medicine (DICOM) image and evaluate and analyze this data.
Conclusion:
A practicable use of such systems is only possible by close cooperation of medical personnel, medical physicists and information technology (IT) administrators. Various systems are available commercially or free but an individual adaptation of these systems is useful and necessary, depending on the requirements of the radiology practice or hospital.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...