Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.6K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

712
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
712
Positron Emission Tomography01:29

Positron Emission Tomography

8.1K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
8.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Intra-fractional Voxel-wise Anatomical Motion Tracking Guided by Multimodal Respiratory Surrogates in Radiotherapy: Framework Development and Multi-Center Validation.

International journal of radiation oncology, biology, physics·2026
Same author

Interlayer-aware postoperative facial appearance prediction in orthognathic surgery with bio-geometric guidance.

Physics in medicine and biology·2026
Same author

A new automated 3d facial soft tissue landmarking method via deep learning.

Journal of dentistry·2026
Same author

Prediction of tumor regression grading in rectal cancer neoadjuvant chemoradiotherapy: a habitat radiomics analysis of imaging biomarker.

BMC medical imaging·2026
Same author

Segmentation-Guided Accelerating Diffusion Model for Cardiac CT Motion Artifact Reduction via Limited-Angle Imaging.

IEEE transactions on medical imaging·2026
Same author

Prior-guided craniofacial soft-tissue reconstruction from CBCT under acquisition uncertainty via identity-quantized shape priors.

Physics in medicine and biology·2026
Same journal

Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

Physics in medicine and biology·2026
Same journal

Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

Physics in medicine and biology·2026
Same journal

Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

Physics in medicine and biology·2026
Same journal

Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

Physics in medicine and biology·2026
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: Apr 5, 2026

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

783

Gamma regularization based reconstruction for low dose CT.

Junfeng Zhang1, Yang Chen, Yining Hu

  • 1Laboratory of Image Science and Technology, Southeast University, Nanjing, People's Republic of China.

Physics in Medicine and Biology
|August 26, 2015
PubMed
Summary
This summary is machine-generated.

This study introduces Gamma regularization for low-dose CT (LDCT) image reconstruction. The novel method effectively reduces noise while preserving image edges, improving diagnostic quality in low-dose scans.

More Related Videos

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

2.9K
Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

13.4K

Related Experiment Videos

Last Updated: Apr 5, 2026

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

783
Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

2.9K
Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

13.4K

Area of Science:

  • Medical Imaging
  • Radiology
  • Image Reconstruction

Background:

  • Radiation reduction in computerized tomography (CT) is a significant concern in modern radiology.
  • Low-dose CT (LDCT) protocols aim to minimize patient radiation exposure.
  • LDCT scans often result in increased image noise, potentially compromising diagnostic accuracy.

Purpose of the Study:

  • To propose a novel Gamma regularization algorithm for enhanced LDCT image reconstruction.
  • To offer a flexible solution balancing l0-norm and l1-norm regularization properties.
  • To evaluate the performance of Gamma regularization in noise suppression and edge preservation for LDCT images.

Main Methods:

  • Development of a Gamma regularization-based algorithm for image reconstruction.
  • Utilizing simulated phantom projection data for algorithm evaluation.
  • Testing the algorithm with projection data from scanned Catphan phantoms.

Main Results:

  • The proposed Gamma regularization algorithm demonstrated superior performance in qualitative and quantitative assessments.
  • Effective noise suppression was achieved in reconstructed LDCT images.
  • Edge-preserving capabilities of the Gamma regularization method were superior to other norm-based approaches.

Conclusions:

  • Gamma regularization presents a robust and effective method for LDCT image reconstruction.
  • The algorithm provides an improved balance between noise reduction and edge preservation compared to existing methods.
  • This approach holds promise for enhancing diagnostic image quality in low-dose CT imaging.