Related Experiment Video
Updated: Apr 5, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Validation of prone myocardial perfusion SPECT with a variable-focus collimator versus supine myocardial perfusion
Tomoko Takamura1, Yoriko Horiguchi2, Masahiko Kanna1
1Department of Cardiology, National Hospital Organization Sagamihara National Hospital, 18-1 Sakuradai, Minami-ku, Sagamihara City, Kanagawa, 252-0392, Japan.
Objective:
The purpose of this study is to evaluate whether prone myocardial perfusion single-photon emission computed tomography (MPS) with thallium-201 acquired through a variable-focus collimator (IQ-SPECT) can correct for soft-tissue attenuation.
Methods:
Thirty-nine patients underwent thallium-201 stress MPS with IQ-SPECT. Delayed images acquired with the patients in the prone position were compared with delayed images obtained with the patients in the supine position with computed tomography-derived attenuation correction (CTAC) (S-CTAC images) or without CTAC (S-NCTAC images). Quantitative tracer uptake (QTU) and semi-quantitative defect scores were determined for the 17 standard myocardial segments. Segments were categorized into anterior-anteroseptal, lateral, inferior, and apex, and areas with defect decision were determined by using the defect scores.
Results:
Image quality in the prone images was similar to that of S-NCTAC and S-CTAC images. In male patients, QTU in prone images was equivalent to that in S-CTAC images in the anterior-anteroseptal area, but was significantly lower than that in S-CTAC images in the inferior area. In female patients, QTU in prone images was similar to that in S-CTAC images in the anterior-anteroseptal, lateral, and inferior areas. In male and in female patients, QTU in the apex was significantly greater in the prone images than that in the S-CTAC images. In the combined male and female patient group, the defect decision for prone images was similar to that for S-CTAC images in the anterior-anteroseptal, lateral, and inferior areas. Apical defects were observed more frequently in S-CTAC images than in prone or S-NCTAC images.
Conclusions:
Fewer artificial defects were observed in the apex of images acquired by prone imaging than by S-CTAC imaging. Prone images improved attenuation and had similar defect decision as S-CTAC images in the anterior-anteroseptal, lateral, and inferior areas.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024