Related Experiment Video
Updated: Apr 5, 2026

Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
Comparison of the extrusion rate of Crawford tubes
Kira L Segal1, Sarah H Van Tassel1, Charles Kim1
1Department of Ophthalmology, Weill Cornell Medical College, New York 10021, USA.
Aim:
To compare the outcomes of dacryocystorhinostomy (DCR) using traditional Crawford tubes (TCT) and Crawford tubes with suture (CTS) in the lumen.
Methods:
Retrospective case series consisting of patients who underwent DCR between 2008 and 2013.
Results:
A total of 61 DCRs were performed on 50 patients. Patients who underwent DCR using CTS had higher rates of prolapse compared to the TCT group (50% vs 9.4%; P=0.003). Stent removal occurred earlier in patients who received CTS (3.3mo vs 5.1mo; P=0.004). Success rates were equivalent between the two groups (75% vs 81.1%; P=0.684).
Conclusion:
CTS in the lumen increases the risk of prolapse, prompting earlier tube removal in patients following DCR for nasolacrimal duct obstruction (NLDO). Earlier removal of tubes does not appear to significantly decrease success rates.