Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Does using two Doppler cardiac output monitors in tandem provide a reliable trend line of changes for validation
Huang Li1, Lester A H Critchley2, Jie Zhang3
1Department of Anaesthesia and Surgical Intensive Care, Peking University First Hospital, Beijing, China.
Abstract:
The demise of the pulmonary artery catheter as a gold standard in cardiac output measurement has created the need for new standard. Doppler cardiac output can be measured suprasternally (USCOM) and via the oesophagus (CardioQ). Use in tandem they may provide a reliable trend line of cardiac output changes against which new technologies can be assessed. Data from three similar clinical studies was pooled. Simultaneous USCOM and CardioQ readings, 13 (7-27), were performed every 15-30 min intraoperatively. Within individual patient regression analysis was performed. Data was normalized, CardioQ against USCOM, to eliminate the systematic error component following calibration. Bland-Altman and trend, concordance and polar analysis, were performed on the grouped data. Cardiac output was indexed (CI) to BSA. Data from 53 patients, aged 59 (26-81) years, scheduled for major surgery were included. Within-individual mean (SD) CI was 3.4 (0.6) L min(-1) m(-2). Correlation was good to excellent in 83 % of cases, R(2) > 0.80, and reasonable in 96 %, R(2) > 0.60. Percentage error was 38 %, and decreased to 14 % with normalization. The estimated 95 % precision for a single Doppler reading was ±10 %. Concordance rate was 96.6 % (confidence intervals 94.7-99.5 %) and above the >92 % threshold for good trending ability. Polar analysis also confirmed good trending ability. The regression line between Doppler methods was offset with a slope of 0.9, thus CardioQ CI readings increased relative to USCOM. Both Doppler methods trended cardiac output reliably. Used in tandem they provide a new standard to assess cardiac output trending.
More Related Videos
09:18Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...