Related Experiment Video
Updated: Apr 4, 2026

Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
Perfusion lung scintigraphy for the prediction of postoperative residual pulmonary function in patients with lung
Katarzyna Kovacević-Kuśmierek1, Józef Kozak, Łukasz Pryt
1Department of Quality Control and Radiological Protection, Medical University of Łódź, Poland. katarinakovacevic@wp.pl.
Background:
Accurate prediction of postoperative pulmonary function in patients with non-small cell lung cancer is crucial for proper qualification for surgery, the only effective therapeutic method. The aim of the study was to select the most accurate method for acquisition and processing of lung perfusion scintigraphy (LPS) combined with spirometry for prediction of postoperative pulmonary function in patients qualified for surgery.
Material And Methods:
LPS was performed in 70 patients (40 males, 30 females), with preoperative spirometry (mean FEV1preop = 2.26 ± 0.72 L), after administration of 185 MBq of 99mTc-microalbumin/macroaggregate, using planar (appa) and SPECT/CT methods. Predicted postoperative lung function (FEV1pred) was calculated as a part of active lung parenchyma to remain after surgery. A non-imaging segment counting method was also applied. FEV1pred(appa, SPECT, SPECT/CT, segm.) were further compared with actual FEV1postop values obtained from postoperative spirometry.
Results:
In the whole studied group (47 lobectomies, 23 pneumonectomies) mean value of FEV1postop was equal to 1.76 (± 0.56) L. FEV1pred(appa, SPECT, SPECT/CT, segm.) were equal to 1.75 (± 0.58) L, 1.71 (± 0.57) L, 1.72 (± 0.57) L and 1.57 (± 0.58) L, respectively. A segment counting method systematically lowered predicted FEV1 values (p < 10-5). Moreover, in 31 patients with FEV1preop < 2 L error of predicted values was assessed with Bland-Altman method. Mean absolute differences FEV1postop - FEV1pred amounted to: appa - (0.04 ± 0.13) L, SPECT - (0.07 ± 0.14) L, SPECT/CT - (0.06 ± 0.14) L and segm. - (0.21 ± 0.19) L, respectively. Lower limit of 95% confidence interval calculated for planar - optimal method, was equal to -220 mL (also determined separately in subgroups after lobectomy and pneumonectomy).
Conclusions:
This study shows that planar LPS may be applied for prediction of postoperative pulmonary function in patients qualified for pneumonectomy and lobectomy. If actual FEV1postop value is to be ≥ 800 mL, predicted value should exceed 1000 mL.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care

