Related Experiment Video
Updated: Apr 4, 2026

Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
[Heparin-induced Thrombocytopenia after Total Arch Replacement]
Masahito Minakawa1, Zaiqiang Yu, Ryosuke Kowatari
1Department of Thoracic and Cardiovascular Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan.
A 71-year-old man underwent total arch replacement for the true aortic arch aneurysm. On the post-operative day (POD) 10, right hemiplegia and motor aphasia occurred, and it was revealed that there were multiple cerebral infarction in brain computer tomography scan and magnetic resonanse imaging. Furthermore, platelet count has declined significantly from POD 15, so we suspected that heparin-induced thrombocytopenia might occurred. Then, we stopped continuous injection of heparin and administered argatroban and warfarin. In blood examinations, anti-platelet factor 4(PF4)/ heparin antibody measured by latex turbidimetry significantly increased at 5.2 U/ml, and specific immunoglobulin G for PF4/ heparin was also significantly high( optical density 2.334, cut off 0.400). Measurement of platelet derived microparticles produced by stimulation using various dose of heparin( functional assay) indicated typical pattern observed in heparin-induced thrombocytopenia. Thereafter, platelet count recovered and the patient recovered without another thromboembolic event.
A 71-year-old man underwent total arch replacement for the true aortic arch aneurysm. On the post-operative day (POD) 10, right hemiplegia and motor aphasia occurred, and it was revealed that there were multiple cerebral infarction in brain computer tomography scan and magnetic resonanse imaging. Furthermore, platelet count has declined significantly from POD 15, so we suspected that heparin-induced thrombocytopenia might occurred. Then, we stopped continuous injection of heparin and administered argatroban and warfarin. In blood examinations, anti-platelet factor 4(PF4)/ heparin antibody measured by latex turbidimetry significantly increased at 5.2 U/ml, and specific immunoglobulin G for PF4/ heparin was also significantly high( optical density 2.334, cut off 0.400). Measurement of platelet derived microparticles produced by stimulation using various dose of heparin( functional assay) indicated typical pattern observed in heparin-induced thrombocytopenia. Thereafter, platelet count recovered and the patient recovered without another thromboembolic event.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...