Related Experiment Video
Updated: Apr 4, 2026

Adsorption Device Based on a Langatate Crystal Microbalance for High Temperature High Pressure Gas Adsorption in Zeolite H-ZSM-5
Published on: August 25, 2016
Zeolite/Fe3O4 as a new sorbent in magnetic solid-phase extraction followed by gas chromatography for determining
Afsaneh Mollahosseini1, Mina Toghroli1, Marzieh Kamankesh1
1Spectroscopy, Micro and Nano-extraction Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran, Iran.
Abstract:
In the present study, for the first time, we successfully employed zeolite/Fe3O4 as a new magnetic nanoparticle sorbent in magnetic solid-phase extraction for determining phthalates in aqueous samples. Gas chromatography with flame ionization detection was used to detect the target analytes as a powerful instrumental analysis. Affecting parameters in the extraction process, including the amount of adsorbent, adsorption and desorption time, and volume of desorption solvent, were optimized using a response surface methodology based on central composite design. Under the optimum conditions, the linear range for dibutyl phthalate and bis(2-ethylhexyl phthalate) was varied in the interval of 10-1700 and 10-1200 μg/L, respectively. Limits of detection were 2.80 μg/L for dibutyl phthalate and 3.20 μg/L for bis(2-ethylhexyl phthalate). The recovery value for the extraction of target analytes was between 97 and 111%. The repeatability and reproducibility of the new proposed method were obtained: 10-13% and 13-13.5%, respectively. The increased sensitivity in using the proposed method has been demonstrated. Compared with previous methods, the new proposed method is an accurate, rapid, and reliable sample-pretreatment method.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Extraction: Advanced Methods
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Analyte Adsorption and Distribution
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Detectors-II