Related Experiment Video
Updated: Jan 21, 2026

Comparison of Two Different Synthesis Methods of Single Crystals of Superconducting Uranium Ditelluride
Published on: July 8, 2021
Evaluation and application of Diffusive Gradients in Thin Films (DGT) technique using Chelex®-100, Metsorb™ and
Jagoda Drozdzak1, Martine Leermakers1, Yue Gao1
1Analytical, Environmental & Geo-Chemistry (AMGC), Vrije Universiteit Brussels (VUB), Pleinlaan 2, 1050, Brussels, Belgium.
Abstract:
A new resin- Diphonix(®) in Diffusive Gradients in Thin Films (DGT) technique for the determination of uranium was investigated and compared with previously used binding phases for uranium, Chelex(®)-100 and Metsorb™. The DGT gel preparation and the elution procedure were optimized for the new resin. The U uptake on Diphonix(®) resin gel was 97.4 ± 1.5% (batch method; [U] = 20 μg L(-1); 0.01 M NaNO3; pH = 7.0 ± 0.2). The optimal eluent was found to be 1 M 1-hydroxyethane-1, 1-diphosphonic acid (HEDPA) with an elution efficiency of 80 ± 4.2%. Laboratory DGT study on U accumulation using a DGT samplers with Diphonix(®) resin showed a very good performance across a wide range of pH (3-9) and ionic strength (0.001-0.7 M NaNO3). Diffusion coefficients of uranium at different pH were determined using both, a diffusion cell and the DGT time-series, demonstrating the necessity of the implementation of the effective diffusion coefficients into U-DGT calculations. Diphonix(®) resin gel exhibits greater U capacity than Chelex(®)-100 and Metsorb™ binding phase gels (a Diphonix(®) gel disc is not saturated, even with loading of 10.5 μmol U). Possible interferences with Ca(2+) (up to 1.33 × 10(-2) M), PO4(3-) (up to 1.72 × 10(-4) M), SO4(2-) (up to 4.44 × 10(-3) M) and HCO3(-) (up to 8.20 × 10(-3) M) on U-DGT uptake ([U] = 20 μg L(-1)) were investigated. No effect or minor effect of Ca(2+), PO4(3-), SO4(2-), and HCO3(-) on the quantitative measurement of U by Diphonix(®)-DGT was observed. The results of this study demonstrated the DGT technique with Diphonix(®) resin is a reliable and robust method for the measurement of labile uranium species under laboratory conditions.
Related Concept Videos
Diffusion
Diffusion
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
The Equilibrium Binding Constant and Binding Strength
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...

