Patient and staff dosimetry during radiographic procedures in an intensive care unit
Rosario Fernández1, Miguel Moreno-Torres, Antonia M Contreras
1Unidad de Cuidados Intensivos, Hospital Universitario San Cecilio, Granada, Spain.
Abstract:
The performance of radiography in the Intensive Care Unit (ICU) may be associated with a certain level of radiation exposure for staff and patients in the unit. Little evidence on exposure levels is available in the literature. However, healthcare professionals in the ICUs at our centre tend to leave the room during radiographic examinations, potentially compromising patient care. The objectives of this study were to quantify dose levels within the ICU and to evaluate the performance of ICU x-ray studies according to patient dose measurements. This study was conducted in the 18-bed ICU of a third-level hospital. The scattering radiation due to mobile x-ray examinations was measured by using four personal thermoluminiscent dosimeters (TLDs). The dose area product (DAP) was measured at each examination using a transmission chamber installed on the diaphragm of the x-ray equipment. Based on the TLD readings and taking account of the error margin, the annual dose to patients and staff was less than 0.6 mSv. The value given by the DAP meter for chest x-rays was 94 ± 17 mGy cm(2); this value is well below the lower limit recommended by different agencies and committees. Exposure levels were found to be extremely low and pose no apparent risk to staff or to those in beds adjacent to the patients undergoing x-ray examinations, which were correctly performed in the unit.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...